Perfusion processes provide consistent culture conditions, high productivity and low product residence times. However, process development can be slow due to the 1 week or more required to reach each steady state. The objective of this work was to accelerate process development in perfusion cultures by scanning non‐steady‐state transient responses to qualitatively predict steady‐state performance. The method was tested using a shift in temperature every 3 days, scanned down by steps of 2°C from 37°C to 31°C, then scanned up to 37°C. Higher t‐PA concentrations were predicted at lower temperatures, confirmed by subsequent pseudo‐steady‐state results. In most cases, transient values on the 3rd day were in close concordance with pseudo‐steady‐state values. To further accelerate process development, transient scanning was applied to small‐scale, non‐instrumented cultures. Similar results were obtained, although quantitative t‐PA values were 15–30 times lower than in high cell density perfusion cultures. The method was further explored by investigating 1 day transient shifts in temperature where more variability was observed, suggesting that the cells were still adapting to the new environment. Nonetheless, the overall response again qualitatively predicted the pseudo‐steady‐state temperature response. Use of transient scanning in conjunction with pseudo‐steady‐state verification and refinement of optimal results could reduce process development time to a third or less of comparable steady‐state‐based optimization.Keywords
This publication has 26 references indexed in Scilit:
- Potential of cell retention techniques for large‐scale high‐density perfusion culture of suspended mammalian cellsBiotechnology and Bioengineering, 2003
- Effect of low culture temperature on specific productivity, transcription level, and heterogeneity of erythropoietin in Chinese hamster ovary cellsBiotechnology and Bioengineering, 2003
- Optimization of an Acoustic Cell Filter with a Novel Air‐Backflush SystemBiotechnology Progress, 2003
- The computer-controlled continuous culture of Escherichia coli with smooth change of dilution rate (A-stat)Journal of Microbiological Methods, 1995
- Transient responses of hybridoma cells in continuous culture to step changes in amino acid and vitamin concentrationsBiotechnology and Bioengineering, 1994
- Effect of temperature on hybridoma cell cycle and MAb productionBiotechnology and Bioengineering, 1992
- The influence of temperature on a mouse–mouse hybridoma growth and monoclonal antibody productionBiotechnology and Bioengineering, 1991
- The transient responses of hybridoma cells to nutrient additions in continuous culture: II. Glutamine pulse and step changesBiotechnology and Bioengineering, 1989
- Transient responses of hybridoma cells to nutrient additions in continuous culture: I. Glucose pulse and step changesBiotechnology and Bioengineering, 1989
- Factors affecting cell growth and monoclonal antibody production in stirred reactorsJournal of Immunological Methods, 1986