Compliance with Electronic Patient Reported Outcome Measure System Data Collection Is 51% Two‐years After Shoulder Arthroscopy
Authors:
Open Access
- 14 December 2022
- journal article
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (1) , e137-e142
Abstract
Objective: To determine patient compliance in completing electronic patient‐reported outcome measures (PROMs) following arthroscopic shoulder surgery and identify risk factors for noncompliance. Methods: A retrospective review of compliance data was performed for patients who underwent arthroscopic shoulder surgery by a single surgeon in a private practice setting from June 2017 to June 2019. All patients were enrolled in Surgical Outcomes System (Arthrex) as a part of routine clinical care, and outcome reporting was integrated into our practice electronic medical record. Patient compliance with PROMs was calculated at preoperative, three‐month, 6‐month, 1‐year, and 2‐year follow‐up time points. Compliance was defined as a complete patient response to each assigned outcome module in the database over time. Logistic regression for compliance at the one‐year timepoint was performed to assess for factors associated with survey compliance. Results: Compliance with PROMs was highest preoperatively (91.1%) and decreased at each subsequent time point. The largest decrease in compliance with PROMs occurred between the preoperative and 3‐month follow‐up time points. Compliance was 58% at 1 year and 51% at 2 years after surgery. Overall, 36% of patients were compliant at all individual time points. There were no significant predictors of compliance with regard to age, sex, race, ethnicity, or procedure. Conclusions: Patient compliance with PROMs decreased over time with the lowest percentage of patients completing electronic surveys at the traditional 2‐year follow‐up for shoulder arthroscopy. In this study, basic demographic factors were not predictive of patient compliance with PROMs. Clinical Relevance: PROMs are commonly collected after arthroscopic shoulder surgery; however, low patient compliance may affect their utility in research and clinical practice.Keywords
This publication has 31 references indexed in Scilit:
- Smoothing Parameter and Model Selection for General Smooth ModelsJournal of the American Statistical Association, 2016
- Electronic Supplementum no 362: ISAR meeting Gothenburg 2015, SwedenActa Orthopaedica, 2016
- Socioeconomic deprivation and age are barriers to the online collection of patient reported outcome measures in orthopaedic patientsThe Annals of The Royal College of Surgeons of England, 2016
- Patient-reported outcome measures unbiased by loss of follow-up. Single-center study based on DaneSpine, the Danish spine surgery registryEuropean Spine Journal, 2015
- Barriers to Completion of Patient Reported Outcome MeasuresThe Journal of Arthroplasty, 2013
- Loss of Follow-Up in Orthopaedic TraumaJournal of Orthopaedic Trauma, 2013
- Lessons Learned From Managing a Prospective, Private Practice Joint Replacement Registry: A 25-year ExperienceClinical Orthopaedics and Related Research, 2013
- Reliability of patient-reported functional outcome in a joint replacement registryActa Orthopaedica, 2013
- Factors associated with non-response in routine use of patient reported outcome measures after elective surgery in EnglandHealth and Quality of Life Outcomes, 2012
- Response Bias: Effect on Outcomes Evaluation by Mail Surveys After Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2004