Differences in displacement of the proximal and distal ends of mid-upper thoracic esophageal squamous cell carcinoma
Authors:
Open Access
- 11 May 2016
- journal article
- Published by Spandidos Publications in Molecular and Clinical Oncology
- Vol. 5 (1) , 143-147
Abstract
In the present study, clips were used as markers to evaluate displacement differences between proximal and distal ends of esophageal tumors and to test whether their internal target volume (ITV) margins should be determined separately. A total of 23 patients with mid-upper thoracic esophageal squamous-cell carcinoma, a tumor length of ≤8 cm and an esophageal lumen suitable for endoscopic ultrasonography were recruited for the present study. Clips were implanted endoscopically at the proximal and distal ends of the esophageal tumor (upper and lower clips). In a further exploratory study on 16 of the patients, a third clip was placed at the distal esophagus 2 cm above the gastro-esophageal junction (GEJ) (cardiac clip). The clips were contoured for all 10 phases of the four-dimensional computed tomography and the maximum displacements of the clip centroids among different breathing phases in left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions were marked as x, y and z, respectively. The ITV margins that covered 95% of the LR, SI and AP motion were 2.89, 5.00 and 2.36 mm, respectively. Axial displacement (y) was greater than radial displacement (x, z; P<0.05). It was also revealed that LR(x), SI(y) and AP(z) displacement of cardiac clips was greater than that of upper or lower clips (P<0.05). Differences in the axial and radial displacement of the upper and lower clips indicated that axial and radial ITV margins should be determined separately. However, further study is required on patients in whom the distal tumor end is located in proximity to the GEJ.Keywords
This publication has 19 references indexed in Scilit:
- A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgeryRadiation Oncology, 2014
- Using four-dimensional computed tomography images to optimize the internal target volume when using volume-modulated arc therapy to treat moving targetsJournal of Applied Clinical Medical Physics, 2012
- Preoperative Chemoradiotherapy for Esophageal or Junctional CancerThe New England journal of medicine, 2012
- Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volumeRadiotherapy and Oncology, 2008
- Determination of Respiratory Motion for Distal Esophagus Cancer Using Four-Dimensional Computed TomographyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Evaluation of respiratory-induced target motion for esophageal tumors at the gastroesophageal junctionRadiotherapy and Oncology, 2007
- Four-dimensional computed tomographic analysis of esophageal mobility during normal respirationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Real-time monitoring of a digestive tract marker to reduce adverse effects of moving organs at risk (OAR) in radiotherapy for thoracic and abdominal tumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Intra- and inter-fraction esophagus motion in 3D-conformal radiotherapy: Implications for ICRU 62 definitions of internal target volume and planning organ at risk volumeInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- INT 0123 (Radiation Therapy Oncology Group 94-05) Phase III Trial of Combined-Modality Therapy for Esophageal Cancer: High-Dose Versus Standard-Dose Radiation TherapyJournal of Clinical Oncology, 2002