A Biomechanical Analysis of Two Biceps Tenodesis Fixation Techniques
Authors:
- 1 July 2005
- journal article
- Published by Wiley in Arthroscopy
- Vol. 21 (7) , 861-866
Abstract
Purpose: To assess and compare the biomechanical properties and load‐to‐failure of 2 biceps tenodesis fixation techniques, interference screw fixation and double suture anchor fixation. Type of Study: Biomechanical study. Methods: Eleven fresh‐frozen human cadaveric specimens were used in this study. A biceps tenodesis was performed using 1 of 2 techniques, interference screw fixation or double suture anchor fixation. A 7‐mm interference screw was used in 5 cadaveric trials. A double suture anchor technique was performed in 6 cadaveric specimens. The tenodesis construct in each specimen was loaded to failure using a Servohydraulic materials test system (MTS Model 858; Bionix, MTS Corp, Minneapolis, MN). Each specimen was loaded at 5 mm/second with a preload of 5 N with the vector of pull distally in line with the long axis of the humerus. Each specimen was then loaded until failure of the repair occurred. Statistical analysis of the interference screw group compared with the suture anchor group was performed using a Student t test. Results: The mode of failure of the interference screw group was variable, but the suture anchor group consistently failed at the anchor or anchor eyelet. The average pullout strength of the suture anchor group was 135.5 ± 37.8 N whereas the failure load in the interference group was 233.5 ± 55.5 N. The interference group had a significantly greater resistance to pullout than the suture anchor group ( P = .007). Conclusions: Based on these results, a biceps tenodesis using an interference screw will provide greater fixation strength than a biceps tenodesis performed with a double suture anchor technique. Clinical Relevance: The surgeon treating biceps tenodesis may wish to choose a fixation technique with higher initial strength (interference screw instead of double suture anchor) to lessen the chance of early failure, particularly if the patient begins early active elbow flexion.Keywords
This publication has 30 references indexed in Scilit:
- Arthroscopic biceps tenodesis with interference screw fixation: The lateral decubitus positionOperative Techniques in Sports Medicine, 2003
- Arthroscopic biceps tenodesis: Indications and techniqueOperative Techniques in Sports Medicine, 2002
- Suture Anchors—Update 1999Arthroscopy, 1999
- Quadrupled semitendinosus‐gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screwArthroscopy, 1998
- Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial boneArthroscopy, 1998
- Internal fixation strength of suture anchors—Update 1997Arthroscopy, 1997
- Role of the long head of the biceps brachii in glenohumeral stability: A biomechanical study in cadaveraJournal of Shoulder and Elbow Surgery, 1996
- Suture anchor strength revisitedArthroscopy, 1996
- The ultimate strength of suture anchorsArthroscopy, 1995
- The Role of the Long Head of the Biceps Muscle and Superior Glenoid Labrum in Anterior Stability of the ShoulderThe American Journal of Sports Medicine, 1994