Enhanced delivery of nebulised salbutamol during non-invasive ventilation
Authors:
- 1 November 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 58 (11) , 1553-1557
Abstract
Non-invasive ventilation (NIV) is used to treat acute respiratory failure. Nebulised drugs can be delivered concurrently with NIV or during breaks from ventilatory support. We hypothesised that the amount of nebulised salbutamol inhaled when delivered via bi-level ventilation would be no different to the amount available directly from the same nebuliser. A standard bi-level ventilation circuit was attached to a lung model simulating adult respiration. Drug delivery was compared when salbutamol (5 mg) was nebulised at different positions in the circuit and separately, with no ventilator. The amount of salbutamol contained in various particle size fractions was also determined. Nebuliser position within the NIV circuit was critically important for drug delivery. Optimal delivery of salbutamol occurred with the expiration port between the facemask and nebuliser (647 ± 67 μg). This was significantly better than nebulisation without the ventilator (424 ± 61 μg; P < 0.01). Delivery when the nebuliser was positioned between the facemask and expiration port was 544 ± 85 μg. The amount of salbutamol contained in particles < 5 μm was significantly increased when the nebuliser was used in conjunction with bi-level ventilation (576 ± 60 μg vs 300 ± 43 μg, P < 0.001). We conclude that nebulised bronchodilator therapy, using a Cirrus jet nebuliser, during bi-level ventilation increases respirable particles likely to be inhaled when the nebuliser is optimally positioned within the circuit.Keywords
This publication has 15 references indexed in Scilit:
- Nebulization associated with Bi-level noninvasive ventilation: Analysis of pulmonary radioaerosol depositionRespiratory Medicine, 2006
- In Vitro Estimations of In Vivo Jet Nebulizer Efficiency Using Actual and Simulated Tidal Breathing PatternsJournal of Aerosol Medicine, 2005
- In vitro evaluation of aerosol bronchodilator delivery during noninvasive positive pressure ventilation: Effect of ventilator settings and nebulizer positionCritical Care Medicine, 2002
- Non-invasive ventilation in acute respiratory failureThorax, 2002
- Optimization of Aerosol Deposition by Pressure Support in Children with Cystic FibrosisAmerican Journal of Respiratory and Critical Care Medicine, 2000
- An in vitro analysis of the output of salbutamol from different nebulizersEuropean Respiratory Journal, 1999
- Intrapulmonary Distribution of Deposited ParticlesJournal of Aerosol Medicine, 1999
- Drug output from nebulizers is dependent on the method of measurementEuropean Respiratory Journal, 1998
- Effects of Noninvasive Ventilation on Pulmonary Gas Exchange and Hemodynamics during Acute Hypercapnic Exacerbations of Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 1997
- Therapeutic Aerosol Delivery during Mechanical VentilationAnnals of Pharmacotherapy, 1996