Risk of Interference from Transcutaneous Electrical Nerve Stimulation on the Sensing Function of Implantable Defibrillators
Authors:
- Christina HolmgrenCHChristina Holmgren
- Clas MannheimerCMClas Mannheimer
- Nils EdvardssonNENils Edvardsson
- 24 January 2008
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (2) , 151-158
Abstract
Background: The use of transcutaneous electrical nerve stimulation (TENS) for pain relief is increasing. At the same time the implantable cardioverter defibrillator (ICD) is a routine treatment for malignant tachyarrhythmias. Today patients often need devices for more than one condition, and consideration must be given to the interaction between them. We studied the risk of interference between TENS and the ICD function. Methods and Results: Thirty patients who had received an ICD underwent a test protocol including TENS at the mammilla and hip levels, at two energy levels, and at the highest comfortable stimulation level. The effects of TENS on the electrocardiogram lead II, intracardiac electrograms, and the ICD marker channels were analyzed. Disturbance from TENS on the sensing function was seen at all stimulation attempts. Interference between the systems was observed in 16 patients. In eight patients (27%) the interpretation was VT/VF and in 14 patients (47%) as ventricular premature extra beats. Other kinds of interactions were seen in five patients (16%). Each patient could have more than one kind of interference. Conclusions: Noise reversion and undersensing might prevent the ICD from delivering shock when it should and the interpretation as VT/VF could result in inappropriate shocks. Because of the potentially serious consequences of interference we do not recommend the use of TENS in patients with ICD.Keywords
This publication has 27 references indexed in Scilit:
- Electrical stimulation of sacral dermatomes in multiple sclerosis patients with neurogenic detrusor overactivityNeurourology and Urodynamics, 2007
- Electrical Stimulation of the Anterior Nucleus of the Thalamus for Intractable Epilepsy: A Long‐term Follow‐up StudyEpilepsia, 2007
- Spinal Cord Stimulation for Refractory Angina in a Patient Implanted with a Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 2007
- ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac DeathJACC, 2006
- Use of an Implantable Cardioverter Defibrillator in a Patient with Two Implanted Neurostimulators for Severe Parkinson's DiseasePacing and Clinical Electrophysiology, 2000
- To the EditorPacing and Clinical Electrophysiology, 1999
- Catecholamine metabolism during pacing-induced angina pectoris and the effect of transcutaneous electrical nerve stimulationAmerican Heart Journal, 1987
- Transcutaneous electrical nerve stimulation (TENS) in angina pectorisPain, 1986
- The effects of transcutaneous electrical nerve stimulation in patients with severe angina pectoris.Circulation, 1985
- Temporary Abolition of Pain in ManScience, 1967