Evaluation of image quality of pituitary dynamic contrast‐enhanced MRI using time‐resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT‐TWIST)
- 18 October 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (5) , 1497-1506
Abstract
Background: Time‐resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k‐space data and view‐sharing for the peripheral k‐space of dynamic phases. IT‐TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction.Purpose: To compare image quality between TWIST and IT‐TWIST in 3D pituitary DCE‐MRI.Study Type: Retrospective observation study.Population: Fifty‐one patients (23 men, 28 women) who underwent 3D pituitary DCE‐MRI using TWIST between July 2016 and April 2017.Field Strength/Sequence: 3T/TWIST and IT‐TWIST.Assessment: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT‐TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT‐TWIST.Statistical Tests: Paired t‐test or Wilcoxon rank‐sum test was used to test the differences between TWIST and IT‐TWIST in both visual evaluation and region of interest evaluation.Results: Scores of visual evaluations for IT‐TWIST were significantly better than those for TWIST (P < 0.001) in all items. Enhancement slope for IT‐TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus (P < 0.001). Temporal SD for IT‐TWIST was significantly lower than that for TWIST in all items, with statistical significance (P < 0.001).Data Conclusion: IT‐TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE‐MRI.Evidence Level: 4Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2020;51:1497–1506.Keywords
This publication has 23 references indexed in Scilit:
- Role of High-Resolution Dynamic Contrast-Enhanced MRI with Golden-Angle Radial Sparse Parallel Reconstruction to Identify the Normal Pituitary Gland in Patients with MacroadenomasAmerican Journal of Neuroradiology, 2017
- High-Resolution DCE-MRI of the Pituitary Gland Using Radialk-Space Acquisition with Compressed Sensing ReconstructionAmerican Journal of Neuroradiology, 2015
- 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imagingEuropean Journal of Radiology, 2014
- Volume interpolated 3D‐spoiled gradient echo sequence is better than dynamic contrast spin echo sequence for MRI detection of corticotropin secreting pituitary microadenomasClinical Endocrinology, 2012
- 3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRAAmerican Journal of Neuroradiology, 2008
- Ectopic posterior pituitary high signal in preoperative and postoperative macroadenomas: dynamic MR imagingEuropean Journal of Radiology, 2005
- Dynamic MR imaging for diagnosis of lesions adjacent to pituitary glandEuropean Journal of Radiology, 2005
- Dynamic MR imaging in Tolosa–Hunt syndromeEuropean Journal of Radiology, 2004
- Pituitary adenomas and normal pituitary tissue: enhancement patterns on gadopentetate-enhanced MR imaging.Radiology, 1990
- Arterial blood supply of the normal human pituitary glandJournal of Neurosurgery, 1983