Accurate Acetabular Component Positioning in Total Hip Arthroplasty Using Preoperative CT and Anatomical Landmarks
Open Access
- 31 August 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6766
Abstract
Background: Accurate acetabular component anteversion during total hip arthroplasty (THA) remains challenging. We evaluated a preoperative computed tomography (CT)–based technique that uses patient-specific acetabular bony landmarks to position the cup. Methods: We prospectively enrolled 48 patients (50 hips) undergoing primary THA between September 2023 and January 2024. On preoperative CT, the anterior acetabular notch (AAN) was defined as the anterior pole, and the point opposite it across the acetabular center was defined as the posterior pole. Using the cup radius (r), the target-relative rotation (θ), and half the interpolar distance (R), the arc-length distances from each pole to the cup margin (a and b) were derived preoperatively with exact circular-geometry equations and reproduced intraoperatively. Postoperative CT anteversion was measured and converted to radiographic anteversion to determine outliers from the Lewinnek safe zone. Early clinical outcomes, including dislocation and modified Harris hip score (mHHS), were assessed at 3 months. Results: Mean postoperative CT anteversion was 25.1° (range, 16.0–35.0°), with a mean absolute error of 4.0° (range, 0–12.0°). Calculated radiographic anteversion was 16.8° (range, 10.0–24.0°), and all 50 hips were within the Lewinnek safe zone. At 3 months, mean mHHS was 92.4, and no dislocations were observed. Conclusions: This prospective proof-of-concept study suggests that CT-based acetabular bony landmarks can enable accurate cup positioning in standard primary THA. Further controlled studies are required to confirm reproducibility and clinical advantage.Keywords
This publication has 25 references indexed in Scilit:
- Determining the orientation of acetabular prosthesis in total hip arthroplasty by refering to the anatomical landmarker of acetabular notchesScientific Reports, 2023
- A retrospective study comparing a single surgeon's experience on manual versus robot-assisted total hip arthroplasty after the learning curve of the latter procedure – A cohort studyInternational Journal of Surgery, 2020
- Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of GuidanceThe Journal of Arthroplasty, 2015
- Precision of Robotic Guided Instrumentation for Acetabular Component PositioningThe Journal of Arthroplasty, 2015
- Acetabular Component Positioning Using Anatomic Landmarks of the AcetabulumClinical Orthopaedics and Related Research, 2012
- Acetabular Component Positioning Using the Transverse Acetabular Ligament: Can You Find It and Does It Help?Clinical Orthopaedics and Related Research, 2011
- The John Charnley Award: Risk Factors for Cup Malpositioning: Quality Improvement Through a Joint Registry at a Tertiary HospitalClinical Orthopaedics and Related Research, 2011
- Imaging and Navigation Measurement of Acetabular Component Position in THAClinical Orthopaedics and Related Research, 2009
- Poor accuracy of freehand cup positioning during total hip arthroplastyArchives of orthopaedic and trauma surgery, 2007
- Pelvic tilt makes acetabular cup navigation inaccurateActa Orthopaedica, 2005