Air Quality and Energy Use in a Museum
Open Access
Abstract
Museums play a vital role in preserving cultural heritage and for this reason, they require strict indoor environmental controls. Balancing indoor environmental quality with reduced energy consumption poses significant challenges. Over the course of a year (2023), indoor microclimate conditions, atmospheric pollutant concentrations (O3, TVOC, CO, CO2, particulate matter), and energy use were monitored at the Archaeological Museum of Kavala. Maximum daily fluctuations in relative humidity were 15% in summertime, while air temperature variations reached 2.0 °C, highlighting unstable microclimatic conditions. Particulate matter was the primary threat to the preservation of artworks, followed by indoor O3 and NO2, whose concentrations exceeded recommended limits for cultural conservation. In 2023, the Energy Use Intensity (EUI) was 86.1 kWh m−2, a value that is significantly correlated with the number of visitors and the outdoor air temperature. Every person visiting the museum was assigned an average of 7.7 kWh of energy. During the hottest days and when the museum was crowded, the maximum amount of energy was consumed. Over the past decade (2013–2023), the lowest EUI was recorded during the COVID-19 pandemic at 53 kWh m−2. Energy consumption is linked to indoor environmental quality; thus, both must be continuously monitored.Keywords
This publication has 60 references indexed in Scilit:
- Factors affecting museum buildings and heritage spaces in terms of energy optimization and comfortAin Shams Engineering Journal, 2024
- A review on inorganic gaseous pollutants in conservation spaces: monitoring instrumentation and indoor concentrationsEnvironmental Monitoring and Assessment, 2023
- Airborne particles, bacterial and fungal communities insights of two museum exhibition halls with diverse air quality characteristicsAerobiologia, 2022
- The impacts of climate change on Greek airportsClimatic Change, 2020
- Multi-objective optimization of microclimate in museums for concurrent reduction of energy needs, visitors’ discomfort and artwork preservation risksApplied Energy, 2018
- Energy conservation in museums using different setpoint strategies: A case study for a state-of-the-art museum using building simulationsApplied Energy, 2015
- Air pollutant emission rates and concentrations in medieval churchesJournal of Atmospheric Chemistry, 2008
- Organic and inorganic pollutants in storage rooms of the Lower Saxony State Museum Hanover, GermanyAtmospheric Environment, 2005
- PM2.5 and associated ionic component concentrations inside the archaeological museum of Thessaloniki, N. GreeceAtmospheric Environment, 2004
- Indoor air pollution: Effects on cultural and historic materialsMuseum Management and Curatorship, 1985