Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series
Authors:
Preprint
Abstract
This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $\Phi_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.
Keywords
All Related Versions
This publication has 13 references indexed in Scilit:
- Radiation damage effect on time resolution of 6 series-connected SiPMs for MEG II positron timing counterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Radiation damage of SiPMsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017Springer Proceedings in Physics, 2018
- 30-ps time resolution with segmented scintillation counter for MEG IINuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Fast SiPM Readout of the PANDA TOF DetectorJournal of Instrumentation, 2016
- Test and characterisation of SiPMs for the MEGII high resolution Timing CounterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Application of the DRS chip for fast waveform digitizingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- “Effective NIEL” in Silicon: Calculation Using Molecular Dynamics Simulation ResultsIEEE Transactions on Nuclear Science, 2010
- Physics and numerical simulation of single photon avalanche diodesIEEE Transactions on Electron Devices, 1997
- Observation of avalanche propagation by multiplication assisted diffusion in p-n junctionsApplied Physics Letters, 1990