Ultrasensitive ImmunoMag-CRISPR Lateral Flow Assay for Point-of-Care Testing of Urinary Biomarkers
- 23 December 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (1) , 92-100
Abstract
Rapid, accurate, and noninvasive detection of biomarkers in saliva, urine, or nasal fluid is essential for the identification, early diagnosis, and monitoring of cancer, organ failure, transplant rejection, vascular diseases, autoimmune disorders, and infectious diseases. We report the development of an Immuno-CRISPR-based lateral flow assay (LFA) using antibody-DNA barcode complexes with magnetic enrichment of the target urinary biomarkers CXCL9 and CXCL10 for naked eye detection (ImmunoMag-CRISPR LFA). An intermediate approach involving a magnetic bead-based Immuno-CRISPR assay (ImmunoMag-CRISPR) resulted in a limit of detection (LOD) of 0.6 pg/mL for CXCL9. This value surpasses the detection limits achieved by previously reported assays. The highly sensitive detection method was then re-engineered into an LFA format with an LOD of 18 pg/mL for CXCL9, thereby enabling noninvasive early detection of acute kidney transplant rejection. The ImmunoMag-CRISPR LFA was tested on 42 clinical urine samples from kidney transplant recipients, and the assay could determine 11 positive and 31 negative urinary samples through a simple visual comparison of the test line and the control line of the LFA strip. The LFA system was then expanded to quantify the CXCL9 and CXCL10 levels in clinical urine samples from images. This approach has the potential to be extended to a wide range of point-of-care tests for highly sensitive biomarker detection.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (U01AI063594, R01AI170424)
This publication has 60 references indexed in Scilit:
- Stabilized glycerol dehydrogenase for the conversion of glycerol to dihydroxyacetoneChemical Engineering Journal, 2015
- Cancer biomarker detection: recent achievements and challengesChemical Society Reviews, 2015
- Aqueous two-phase systems enable multiplexing of homogeneous immunoassaysTECHNOLOGY, 2014
- Development and Applications of CRISPR-Cas9 for Genome EngineeringCell, 2014
- Advances in paper-based point-of-care diagnosticsBiosensors and Bioelectronics, 2014
- Biomarkers for kidney transplant rejectionNature Reviews Nephrology, 2014
- Urine proteomics in kidney transplantationTransplantation Reviews, 2014
- Multicenter Validation of Urinary CXCL9 as a Risk-Stratifying Biomarker for Kidney Transplant InjuryAmerican Journal of Transplantation, 2013
- Point of Care Diagnostics: Status and FutureAnalytical Chemistry, 2011
- Difficulties with determining the detection limit with nonlinear calibration curves in spectrometryAnalytical Chemistry, 1976