Abstract
This study involves an investigation into issues that may be encountered when using backfill in mechanically stabilized earth (MSE) walls as a heat sink for spurious heat generated by nearby industrial facilities or buildings. The deformation behavior of thermally active MSE walls is evaluated using a simplified analytical model adapted to consider the effects of temperature, confining stress, and unsaturated soil conditions on the stiffness of geosynthetic-reinforcing elements. The major conclusions that can be drawn from the model results are that it is important to select a geosynthetic that has a high glass-transition temperature and that confining effects of unsaturated backfill may lead to a reduction in the thermal deformations of the geosynthetic.

This publication has 10 references indexed in Scilit: