Background: Accurate repeat assessment of the diameter of an abdominal aortic aneurysm (AAA) is important. This study investigated the reproducibility of different methods of measuring AAA diameter from ultrasound images. Methods: Fifty AAA patients were assessed by ultrasound. Maximum AAA diameter was measured independently by three trained observers on two separate occasions using a standardised protocol. Five diameters were measured from each scan, three in the anterior–posterior (AP) and two in the transverse (TV) plane, including inner-to-inner (ITI), outer-to-outer (OTO) and leading edge-to-leading edge (LETLE). Intra- and inter-observer reproducibility were reported as reproducibility coefficients. Statistical comparison of methods was performed using linear mixed effects models. Results: Intra-observer reproducibility coefficients (AP LETLE 2.2 mm; AP ITI 2.4 mm; AP OTO 2.6 mm) were smaller than inter-observer reproducibility coefficients (AP LETLE 4.6 mm: AP ITI 4.5; and AP OTO 4.8 mm). There was no statistically significant difference in intra-observer reproducibility of three types of measurements performed in the AP plane. Measurements obtained in the TV plane had statistically significant worse intra-observer reproducibility than those performed in the AP plane. Conclusions: This study suggests that the comparison of maximum AAA diameter between repeat images is most reproducibly performed by a single trained observer measuring diameters in the AP plane.Keywords
Funding Information
- National Health and Medical Research Council (1079369, 1098717, 1180736, 1117061 and 1022752)
- Queensland Government (SCRF)
This publication has 36 references indexed in Scilit:
- Ultrasound Measurement of Aortic Diameter in a National Screening ProgrammeEuropean Journal of Vascular and Endovascular Surgery, 2011
- The Swedish experience of screening for abdominal aortic aneurysmJournal of Vascular Surgery, 2011
- Internal or external wall diameter for abdominal aortic aneurysm screening?The Annals of The Royal College of Surgeons of England, 2010
- Abdominal Aortic Aneurysm ExpansionCirculation, 2004
- The Validity of Ultrasonographic Scanning as Screening Method for Abdominal Aortic AneurysmEuropean Journal of Vascular and Endovascular Surgery, 1999
- Growth rates and risk of rupture of abdominal aortic aneurysmsBritish Journal of Surgery, 1998
- Improved reliability of ultrasonic surveillance of abdominal aortic aneurysmsEuropean Journal of Vascular and Endovascular Surgery, 1997
- Interobserver variability in measuring the dimensions of the abdominal aorta: Comparison of ultrasound and computed tomographyEuropean Journal of Vascular and Endovascular Surgery, 1996
- Accuracy of ultrasonographic measurement of infrarenal abdominal aortic aneurysmBritish Journal of Surgery, 1994
- Limitations of ultrasonography in surveillance of small abdominal aortic aneurysmsBritish Journal of Surgery, 1991