Reduction in number of devices for symmetrical and asymmetrical multilevel inverters
Open Access
- 1 March 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 9 (4) , 698-709
Abstract
Multilevel inverter (MLI) is receiving remarkable recognition due to its reduced voltage stress across the power switches and low total harmonic distortion in output voltage. However, MLI incorporates large number of semiconductor switches and hence increases its complexity. In this study, new structures of symmetrical and asymmetrical MLI are proposed. The proposed structures offer reduced number of controlled switches, power diodes, capacitors and DC sources as compared with classical and recently proposed topologies in the line. Reduction of switch count, driver circuit and DC voltage sources reduces the size, cost, complexity and enhances overall performance. Moreover significant reduction in voltage stress across the switches can be achieved. A comparative analysis of proposed topologies with the classical topology and recently published topologies has been made in terms of controlled switches, power diodes, driver circuit requirement, DC voltage sources and blocking voltage. Multi‐carrier pulse width modulation strategy is adopted for generating the switching pulses. The detailed simulation study of the proposed topology has been carried out using MATLAB/Simulink and feasibility of topology has been validated experimentally.Keywords
This publication has 32 references indexed in Scilit:
- Comprehensive review of a recently proposed multilevel inverterIET Power Electronics, 2014
- Thirteen‐level cascaded H ‐bridge inverter operated by Generic phase shifted pulse‐width modulationIET Power Electronics, 2013
- Cascaded two-level inverter-based multilevel static VAr compensator using 12-sided polygonal voltage space vector modulationIET Power Electronics, 2012
- Multilevel dodecagonal space-vector generation for induction motor drives by cascading three-level and two-level invertersIET Power Electronics, 2012
- Thermal optimised modulation methods of three-level neutral-point-clamped inverter for 10 MW wind turbines under low-voltage ride throughIET Power Electronics, 2012
- Research on a cascaded multilevel inverter by employing three-phase transformersIET Power Electronics, 2012
- Pulse-based dead-time compensation method for self-balancing space vector pulse width-modulated scheme used in a three-level inverter-fed induction motor driveIET Power Electronics, 2011
- Multilevel inverters for low-power applicationIET Power Electronics, 2011
- Half-wave symmetry selective harmonic elimination method for multilevel voltage source invertersIET Power Electronics, 2011
- A DC–DC multilevel boost converterIET Power Electronics, 2010