Evaluation of Dimensional Stability and Accuracy of Autoclavable Polyvinyl Siloxane Impression Material
Authors:
Open Access
- 7 August 2012
- journal article
- research article
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 13 (4) , 546-550
Abstract
Dimensionally stable autoclavable impressions will be effective in controlling the cross-infection and contamination caused by patient’s saliva and other oral secretions. The accuracy of newly introduced autoclavable polyvinyl siloxane impression material was assessed for its dimensional stability and accuracy. A standard metal model (Dentoform, U-501, Columbia) was customised for impression making. The impressions were made using the newly introduced polyvinyl siloxane impression materials (AFFINIS, Coltene/Whaledent AG, 9450 Alstalten, Switzerland). Fifty impressions were made and were divided into two groups A and B of 25 each. Group A was the control sample (non-autoclaved impressions) and group B was the test sample (autoclaved impressions), which was subjected to the steam autoclave procedure at 134 °C for 18 min, casts were poured in type IV gypsum products. The customised metal model, casts obtained from control and test group were subjected to laboratory evaluation with help of a travelling microscope (×10 magnification), and digital vernier calliper (0.01 mm/10 μm accuracy). Data analysis was done using one-way ANOVA and One-Sample t test to evaluate the overall accuracy (P < 0.005). As a result, there was an average reduction of 0.016 μm in overall dimension between the test and the control group when compared with the master model, which is not statistically or clinically significant. The newly introduced polyvinyl siloxane impression material is accurate and dimensional stable for clinical use when steam autoclaved at 134 °C for 18 min.Keywords
This publication has 16 references indexed in Scilit:
- A comparative study of inter-abutment distance of dies made from full arch dual-arch impression trays with those made from full arch stock trays: An in vitro studyIndian Journal of Dental Research, 2009
- Accuracy of impression and pouring techniques for an implant-supported prosthesis.2008
- Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: An in vitro studyThe Journal of Prosthetic Dentistry, 2008
- Antimicrobial effect of 4 disinfectants on alginate, polyether, and polyvinyl siloxane impression materials.2007
- Reproducibility of sterilized rubber impressionsBrazilian Dental Journal, 2004
- Dimensional stability of a polyvinylsiloxane impression material following ethylene oxide and steam autoclave sterilizationThe Journal of Prosthetic Dentistry, 1991
- Improving the fit of crowns with die spacersThe Journal of Prosthetic Dentistry, 1989
- Dimensional changes of elastomers during cold sterilizationThe Journal of Prosthetic Dentistry, 1987
- Disinfection method for impression materials: Freedom from fear of hepatitis B and acquired immunodeficiency syndromeThe Journal of Prosthetic Dentistry, 1986
- The accuracy of stone dies made from rubber impression materialsThe Journal of Prosthetic Dentistry, 1970