Abstract
The corrosion resistance of Al‐Mg‐Si/SiCp composites produced by the pressureless infiltration method [using SiCp preforms with 50% porosity containing rice hull ash (RHA) and four custom‐made alloys with varying Si/Mg molar ratio] was evaluated in neutral 0.1 M NaCl solutions. The deleterious phase Al4C3 was successfully suppressed in composites with Si/Mg molar ratios of 0.89 and 1.05, but not in those with lower Si/Mg molar ratios (0.12 and 0.49). Results of cyclic polarizations in deareated 0.1 M NaCl solutions showed that with increasing Si/Mg molar ratio, passive current density increased but pitting susceptibility decreased both for reinforced and unreinforced alloys. Immersion tests in aerated 0.1 M NaCl showed that for composites with Si/Mg molar ratios of 0.12 and 0.49 chemical degradation by hydrolysis of Al4C3 was followed by intense anodic dissolution at the matrix–reinforcement interface, while composites corresponding to Si/Mg molar ratios of 0.89 and 1.05 did not exhibit intense localized attack. Possible reasons for the improvement in resistance to localized corrosion are discussed.
Funding Information
  • National Council of Science and Technology, Mexico (51303-Y)

This publication has 28 references indexed in Scilit: