Body temperature and outcome after stroke thrombolysis

Authors:

Abstract
We studied whether baseline body temperature and temperature increases after stroke adversely affect outcome after thrombolysis with intravenous tissue plasminogen activator (IV tPA). The evolution of body temperature in the first 24 h after treatment with IV tPA was described by calculating the area under the curve of the temperature over time plot relative to temperature at admission (AUCBL) and relative to a standard value of 37 degrees C (AUC37). Temperature parameters were related to functional outcome. The median baseline National Institutes of Health Stroke Scale of 100 consecutive patients was 16 (interquartile range 11-21) and 34 patients had a favourable response to tPA. Patients with an unfavourable outcome had a more important temperature elevation than patients who had a favourable outcome after tPA (+1 degrees C vs +0.6 degrees C, P=0.02), despite similar baseline T and had a higher AUCBL (9.79 vs 5.36, P=0.027) and more frequently showed hyperthermia relative to baseline (82% vs 56%, P=0.011). After adjustment for baseline characteristics, the presence of hyperthermia relative to baseline was associated with a reduced odds of good outcome after thrombolysis (OR 0.34, 95% CI 0.10-0.95, P=0.040). Hyperthermia relative to baseline temperature in the 24 h after intravenous thrombolysis is associated with an unfavourable outcome.

This publication has 22 references indexed in Scilit: