Radioactive Seed Localization for Nonpalpable Breast Lesions: Review of 1,000 Consecutive Procedures at a Single Institution
Authors:
- 27 September 2011
- journal article
- review article
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 18 (11) , 3096-3101
Abstract
Radioactive seed localization (RSL) is an alternative to wire localization for nonpalpable breast lesions, with reported lower rates of positive surgical margins. A retrospective review of all consecutive RSL procedures performed at a single institution from 01/2003 through 10/2010 was conducted. One thousand RSL breast procedures were performed in 978 patients. Indications for RSL included invasive carcinoma (52%), in situ carcinoma (22%), atypical hyperplasia (11%), and suspicious percutaneous biopsy findings (15%). A total of 1,148 seeds were deployed using image guidance, with 76% placed ≥1 day before surgery. Most procedures (86%) utilized one seed. A negative margin was achieved at the first operation in 97% of patients with invasive carcinoma and 97% of patients with ductal carcinoma in situ (DCIS). An additional 9% of patients with invasive carcinoma and 19% of patients with DCIS had close (≤2 mm) margins, and underwent re-excision. Sentinel lymph node biopsy was successfully performed in 99.8% of cases. Adverse events included 3 seeds (0.3%) not deployed correctly on first attempt and 30 seeds (2.6%) displaced from the breast specimen during excision of the targeted lesion. All seeds were successfully retrieved, with no radiation safety concerns. Local recurrence rates were 0.9% for invasive breast cancer and 3% for DCIS after mean follow-up of 33 months. There was no evidence of a learning curve. RSL is a safe, effective procedure that is easy to learn, with a low incidence of positive/close margins. RSL should be considered as the method of choice for localization of nonpalpable breast lesions.Keywords
This publication has 20 references indexed in Scilit:
- Current status of radioactive seed for localization of non palpable breast lesionsThe American Journal of Surgery, 2010
- Migration of Guidewire After Surgical Breast Biopsy: An Unusual Case ReportCardioVascular and Interventional Radiology, 2009
- Migration of the breast biopsy localization wire to the pulmonary hilusActa Radiologica, 2005
- Unusual migration in abdomen of a wire for surgical localization of breast lesionsActa Radiologica, 2004
- Localization Wire Migrating into the Hilum of the Lung During Wire-Guided Breast BiopsyThe Breast Journal, 2004
- Localization of impalpable breast lesions—a surgical approachEuropean Journal of Surgical Oncology, 1996
- Migration of localizing wires used in guided biopsy of the breastClinical Radiology, 1991
- Complications of Needle Localization of Foreign Bodies and Nonpalpable Breast LesionsArchives of Surgery, 1988
- Transection of the localization hooked wire during breast biopsyAmerican Journal of Roentgenology, 1983
- Transgression of localizing wire into the pleural cavity prior to mammographyBritish Journal of Radiology, 1981