Microbiological analysis of bacterial sealing of internal conical implants with different taper angles
Authors:
- Alexandre Marcelo de CarvalhoACAlexandre Marcelo de Carvalho
- Bruno Salles Sotto-MaiorBSBruno Salles Sotto-Maior
- Carlos Eduardo FrancischoneCFCarlos Eduardo Francischone
- Elizabeth Ferreira MartinezEMElizabeth Ferreira Martinez
- André Luiz DiasADAndré Luiz Dias
- Liliane Pacheco de CarvalhoLCLiliane Pacheco de Carvalho
Open Access
- 1 January 2023
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 37, e43
Abstract
The present study evaluated the effect of the taper angle of different internal conical connection implants and cyclic loading on the implant-abutment bacterial seal. A total of 96 implant-abutment sets were divided into eight groups. Four groups of different taper degrees with cyclic mechanical loading of 500,000 cycles per sample, with a 120-N load at 2 Hz before analysis [16DC (16-degree, cycled), 11.5DC (11.5-degree, cycled), 3DC (3- degree, cycled) and 4DC (4- degree, cycled)] were compared to four control groups without cyclic loading [16D (16-degree), 11.5D (11.5-degree), 3D (3-degree), and 4D (4-degree)]. Microbiological analysis was performed by immersing all samples in a suspension containing Escherichia coli and incubating them at 37°C. After 14 days, the presence of bacterial seals was evaluated. Fisher-Freeman-Halton exact tests and binomial tests were performed (5% significance level). The groups showed significant differences in bacterial seal, and mechanical load cycling improved the bacterial seal in the 3DC group. In all other groups, no significant differences in bacterial seal were found between cycled and uncycled samples. To conclude, the internal conical connection with a 3-degree taper angle showed better results than the other connection with different angles when subjected to load cycling. However, none of the angles tested were fully effective in sealing the implant-abutment interface.Keywords
This publication has 24 references indexed in Scilit:
- Evaluation of the Sealing Capability of the Implant Healing Screw by Using Real Time Volatile Organic Compounds Analysis: Internal Hexagon Versus Cone MorseJournal of Periodontology, 2016
- Microbiological Seal of Two Types of Tapered Implant ConnectionsBrazilian Dental Journal, 2016
- In vitro analysis of the microbiological sealing of tapered implants after mechanical cyclingClinical Oral Investigations, 2016
- The Effect of Dynamic Loading on Bacterial Colonization of the Dental Implant Fixture–Abutment Interface: An In Vitro StudyJournal of Oral Implantology, 2014
- In Vitro Microbiological Analysis of Bacterial Seal at the Implant-Abutment Interface Using Two Morse Taper Implant ModelsBrazilian Dental Journal, 2014
- The Role of Chlorhexidine on Endotoxin Penetration to the Implant‐Abutment Interface (IAI)Clinical Implant Dentistry and Related Research, 2013
- Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro studyClinical Oral Implants Research, 2013
- One hundred and fifty years of history of the Morse taper: from Stephen A. Morse in 1864 to complications related to modularity in hip arthroplastyInternational Orthopaedics, 2013
- Dental Implants with Conical Implant-Abutment Interface: Influence of the Conical Angle Difference on the Mechanical Behavior of the ImplantThe International Journal of Oral and Maxillofacial Implants, 2013
- Influence of the coating material on the loosing of dental implant abutment screw jointsMaterials Science and Engineering: C, 2006