Tandem mass spectrometric accurate mass performance of time‐of‐flight and Fourier transform ion cyclotron resonance mass spectrometry: a case study with pyridine derivatives
Authors:
- 5 September 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (19) , 1840-1848
Abstract
The interpretation of mass spectra is a key process during compound identification, and the combination of tandem mass spectrometry (MS/MS) with high‐accuracy mass measurements may deliver crucial information on the identity of a compound. Obtaining accurate mass data of fragment ions in MS/MS reveals the particular problem of mass calibration when a lockmass, which is frequently used to obtain accurate masses in MS, is absent. An alternative technique is to recalibrate the MS/MS spectrum using a reference MS/MS spectrum acquired under the same conditions. We have tested and validated this approach using a hybrid quadrupole/orthogonal acceleration reflectron‐type time‐of‐flight (TOF) mass spectrometer. The results were compared with those obtained under similar conditions on a Fourier transform ion cyclotron resonance (FT‐ICR) instrument. We found that the mass accuracy observed with such an ‘external’ recalibration on the TOF instrument in MS/MS is identical to what can be obtained on a similar instrument operating in one‐dimensional MS mode using the lockmass technique. However, mass accuracy in both cases is one order of magnitude inferior to that obtained using FTMS, and also inferior to that observed using sector field MS when operated at comparable resolution. Nevertheless, for small (<200 Da) molecules, this mass accuracy was still sufficient to have the ‘true’ elemental composition identified as the first hit in about 70% of all cases. It was possible to elucidate the fragmentation mechanism of eight azaheterocycles containing a pyridine moiety, where the accurate mass data from the TOF instrument allowed distinction between two alternative fragmentation pathways. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometerJournal of the American Society for Mass Spectrometry, 1999
- Advantages of Pressurization in Capillary Electrophoresis/Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 1999
- Automated high resolution mass spectrometry for the synthetic chemistJournal of the American Society for Mass Spectrometry, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Determination of 4-Hydroxy-2,5-dimethyl-3(2H)-furanone and 2(or 5)-Ethyl-4-hydroxy-5(or 2)-methyl-3(2H)-furanone in Pentose Sugar-Based Maillard Model Systems by Isotope Dilution AssaysJournal of Agricultural and Food Chemistry, 1997
- Analysis of water-soluble vitamins by high-performance liquid chromatography–particle beam-mass spectrometryAnalytical Communications, 1996
- Enhanced mass resolution in a quadrupole ion trapRapid Communications in Mass Spectrometry, 1993
- Electrospray ionization/magnetic sector mass spectrometry: calibration, resolution, and accurate mass measurementsAnalytical Chemistry, 1992
- The ideal mass analyzer: Fact or fiction?International Journal of Mass Spectrometry and Ion Processes, 1987
- Kinetics of displacement reactions with pyridines as both leaving group and nucleophileJournal of the Chemical Society, Perkin Transactions 2, 1979