Suspected Implant-Related Metal Hypersensitivity Following Anterior Cervical Discectomy and Fusion: A Case Report
Open Access
Abstract
Background: Metal hypersensitivity to spinal implants is a rare complication documented predominantly in isolated case reports. While nickel, cobalt, and chromium are the most commonly implicated allergens, titanium alloys used in cervical fusion constructs may also elicit immune-mediated responses. Standalone cages, a common choice in anterior cervical discectomy and fusion (ACDF), are primarily composed of titanium alloy, making them a potential source of metal sensitization. Case Description: We present the case of a patient who underwent ACDF using a standalone titanium alloy cage for cervical spondylotic radiculopathy. Postoperatively, the patient experienced atypical, difficult-to-explain pain with a radiating quality that was inconsistent with the expected surgical recovery pattern. Further history revealed an antecedent self-reported sensitivity to certain jewelry metals. The patient was returned to the operating theatre, the standalone cage was removed, and reconstruction was performed using an iliac crest autograft. Postoperatively, the patient reported notable symptom improvement. As an exploratory observation, a titanium screw from the implant was placed in contact with the patient’s skin, and localized erythema developed within 24 h, providing suspicion of metal hypersensitivity. Conclusions: This case highlights the importance of eliciting a thorough preoperative allergy history, including reactions to jewelry and metal-containing items, before performing instrumented spinal fusion. When metal hypersensitivity is suspected postoperatively, implant removal and replacement with alternative materials might be considered. Skin contact testing may provide helpful adjunctive clues to guide the diagnostic process in suspected metal hypersensitivity.Keywords
This publication has 15 references indexed in Scilit:
- Biomaterials in Spinal Implants: A ReviewNeurospine, 2020
- Suspected allergy to titanium after anterior cervical discectomy and fusion using a Zero-P device: a case reportBritish Journal Of Neurosurgery, 2020
- Allergy to Surgical ImplantsClinical Reviews in Allergy & Immunology, 2018
- Hypersensitivity to Orthopedic Implants: A Review of the LiteratureRheumatology and Therapy, 2017
- Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivityContact Dermatitis, 2016
- Delayed hypersensitivity reaction after cervical disc replacement: A case reportOrthopaedics & Traumatology: Surgery & Research, 2015
- Biomaterial Hypersensitivity: Is It Real? Supportive Evidence and Approach Considerations for Metal Allergic Patients following Total Knee ArthroplastyBioMed Research International, 2015
- Metal hypersensitivity in patient with posterior lumbar spine fusion: a case report and its literature reviewBMC Musculoskeletal Disorders, 2014
- Hypersensitivity reactions to metallic implants – diagnostic algorithm and suggested patch test series for clinical useContact Dermatitis, 2011
- Metal Degradation ProductsClinical Orthopaedics and Related Research, 2003