Screen‐Printed Disposable Sensors Modified with Bismuth Precursors for Rapid Voltammetric Determination of 3 Ecotoxic Nitrophenols
- 13 March 2014
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 26 (4) , 766-775
Abstract
This work reports the application of screen‐printed electrodes bulk‐modified with bismuth precursors to the voltammetric determination of 2‐nitrophenol (2‐NP), 4‐nitrophenol (4‐NP) and 2,4‐dinitrophenol (2,4‐DNP) in water samples. A bismuth film was formed at the electrode surface via in situ reduction of the precursor compound contained in the electrode matrix by cathodic polarization at −1.20 V. The formation of bismuth layer at the precursor‐modified electrodes was assessed by cyclic voltammetric (CV) at different pH values and by optical techniques. The target nitrophenols were voltammetrically determined by recording their reduction peaks in the differential pulse (DP) mode. The composition and content of the precursor compounds in the printed ink and the effect of the pH of the supporting electrolyte on the DP reduction currents of the 3 target nitrophenols were studied. The limits of quantification (LOQs) in three water matrices (distilled water, tap water and surface water) were in the range 1.1–2.2 µmol L−1. Using a simple solid‐phase extraction (SPE) procedure with Lichrolut EN cartridges and elution with methanol, a preconcentration factor of 100 was achieved; the LOQs were 0.021, 0.027 and 0.025 µmol L−1 for 2‐NP, 4‐NP and 2,4‐DNP, respectively. The recoveries of samples spiked with the 3 target nitrophenols at two concentration levels (0.04 and 0.1 µmol L−1) were always >87 %.Keywords
This publication has 26 references indexed in Scilit:
- Disposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II)Analytica Chimica Acta, 2012
- Microbial biosensor for detection of methyl parathion using screen printed carbon electrode and cyclic voltammetryBiosensors and Bioelectronics, 2011
- Crystallic silver amalgam – a novel electrode materialThe Analyst, 2011
- Desenvolvimento de metodologia analítica baseada em eletrodo de carbono vítreo modificado com filme de bismuto: aplicação em águas de chuva de regiões de Santa CatarinaEcletica Quimica, 2011
- Disposable Bismuth Oxide Screen Printed Electrodes for the High Throughput Screening of Heavy MetalsElectroanalysis, 2009
- Investigation of the enzyme hydrolysis products of the substrates of alkaline phosphatase in electrochemical immunosensingTalanta, 2008
- Simultaneous determination of nitrobenzene and nitro-substituted phenols by differential pulse voltammetry and chemometricsAnalytica Chimica Acta, 2001
- Determination of 2-Nitrophenol, 4-Nitrophenol, 2-Methoxy-5-nitrophenol, and 2,4-Dinitrophenol by Differential Pulse Voltammetry and Adsorptive Stripping VoltammetryCollection of Czechoslovak Chemical Communications, 1994
- Voltammetric methods for the determination of foreign organic compounds of biological significance. A reviewThe Analyst, 1978
- Über die polarographische Bestimmung von Parathion und seinem Metabolit p-Nitrophenol in BlutextraktenMicrochimica Acta, 1975