Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating
Authors:
Open Access
- 6 July 2015
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (7) , 1359-1365
Abstract
Central line associated bloodstream infections (CLABSIs) are a serious cause of morbidity and mortality induced by the use of central venous catheters (CVCs). Nobel metal alloy (NMA) coating is an advanced surface modification that prevents microbial adhesion and growth on catheters and thereby reduces the risk of infection. In vitro microbiological analyses have shown up to 90% reduction in microbial adhesion on coated CVC compared to uncoated ones. This study aimed to assess the blood compatibility of NMA‐coated CVC according to ISO 10993‐4. Hemolysis, thrombin–antithrombin (TAT) complex, platelet counts, fibrin deposition, and C3a and SC5b‐9 complement activation were analyzed in human blood exposed to the NMA‐coated and control CVCs using a Chandler‐loop model. NMA‐coated CVC did not induce hemolysis and fell in the “nonhemolytic” category according to ASTM F756‐00. Significantly lower amounts of TAT were generated and less fibrin was deposited on NMA‐coated CVC than on uncoated ones. Slightly higher platelet counts and lower complement markers were observed for NMA‐coated CVC compared to uncoated ones. These data suggest that the NMA‐coated CVC has better ex vivo blood compatibility compared to uncoated CVC. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1359–1365, 2016.Keywords
This publication has 26 references indexed in Scilit:
- A study on device-related infections with special reference to biofilm production and antibiotic resistanceJournal of Global Infectious Diseases, 2012
- Immune complement activation is attenuated by surface nanotopographyInternational Journal of Nanomedicine, 2011
- Infection prevention in the intensive care unit: Review of the recent literature on the management of invasive devicesScandinavian Journal of Infectious Diseases, 2011
- Prevention and control of biofilm-based medical-device-related infectionsFEMS Immunology & Medical Microbiology, 2010
- Blood Interactions with Noble Metals: Coagulation and Immune Complement ActivationACS Applied Materials & Interfaces, 2009
- The artificial surface‐induced whole blood inflammatory reaction revealed by increases in a series of chemokines and growth factors is largely complement dependentJournal of Biomedical Materials Research Part A, 2007
- Optimal heparin surface concentration and antithrombin binding capacity as evaluated with human non‐anticoagulated blood in vitroJournal of Biomedical Materials Research Part A, 2003
- Catheter‐related infection and thrombosis of the internal jugular vein in hematologic‐oncologic patients undergoing chemotherapyCancer, 2001
- Amplification of the Inflammatory Response: Adhesion Molecules Associated with Platelet/White Cell ResponsesJournal of Cardiovascular Pharmacology, 1996
- Prevention of Catheter-related Infections by Silver Coated Central Venous Catheters in Oncological PatientsZentralblatt für Bakteriologie, 1995