Abstract
Background: Strategies to reduce platelet (PLT) bacterial contamination include donor screening, skin disinfection, sample diversion, bacterial culture, pathogen reduction (PR), and day‐of‐transfusion tests. We report bacterial sepsis following a pathogen‐reduced PLT transfusion.Case Report: An adult male with relapsed acute lymphoblastic leukemia was successfully treated for central catheter–associated Staphylococcus aureus bacteremia. A peripherally inserted central catheter (PICC) was placed. Chills, rigors, and flushing developed immediately after PICC‐infused pathogen‐reduced PLTs, progressing to septic shock requiring intensive care management.Methods: PICC and peripheral blood (PB), transfused bag saline flushes (TBFs), environmental samples, and the pathogen‐reduced untransfused co‐component (CC) were cultured. Plasma metagenomic and bacterial isolate whole‐genome sequencing; PLT mitochondrial DNA (mtDNA) testing of untransfused CC and TBF; CC testing for amotosalen (S‐59)/S‐59 photoproducts; isolate PR studies (INTERCEPT); and TBF polymerase chain reaction for recipient Y‐chromosome DNA were performed.Results: PB and PICC cultures grew Acinetobacter calcoaceticus/baumannii complex (ACBC). TBF was gram‐positive; mass spectrometry identified ACBC and Staphylococcus saprophyticus (SS). CC Gram stain and cultures were negative. Environmental cultures, some done after decontamination, were ACBC/SS negative. Posttransfusion patient plasma and TBF ACBC sequences were genetically identical. No Y‐chromosome signal was detected in TBF. S‐59 photoproducts and evidence of mtDNA amplification inhibition were found in the CC. Spiking PR studies showed >5.9‐log inactivation for both isolates. Donor skin cultures for Acinetobacter were negative.Conclusion: CC sterility, PR studies, residual S‐59 photoproducts, and mtDNA amplification inhibition suggest successful PR. Unidentified environmental sources and inherent or acquired bag defects may have contributed to postmanufacturing pathogen‐reduced PLT contamination.Keywords
This publication has 29 references indexed in Scilit:
- Sepsis Attributed to Bacterial Contamination of Platelets Associated with a Potential Common Source — Multiple States, 2018MMWR. Morbidity and Mortality Weekly Report, 2019
- Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance ModuleTransfusion Medicine Reviews, 2019
- Fatal Sepsis Associated with Bacterial Contamination of Platelets — Utah and California, August 2017MMWR. Morbidity and Mortality Weekly Report, 2018
- Implementation of secondary bacterial culture testing of platelets to mitigate residual risk of septic transfusion reactionsTransfusion, 2018
- Routine use of Day 6 and Day 7 platelets with rapid testing: two hospitals assess impact 1 year after implementationTransfusion, 2018
- Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactionsTransfusion, 2017
- Hemovigilance monitoring of platelet septic reactions with effective bacterial protection systemsTransfusion, 2017
- Misinterpretation of Gram Stain from the Stationary Growth Phase of Positive Blood Cultures for Brucella and Acinetobacter SpeciesThe Open Microbiology Journal, 2017
- Bacterial screening of platelet components by National Health Service Blood and Transplant, an effective risk reduction measureTransfusion, 2017
- Routine bacterial screening of apheresis platelets on Day 4 using a rapid test: a 4‐year single‐center experienceTransfusion, 2013