Clinical performance during 48 months of two current glass ionomer restorative systems with coatings: a randomized clinical trial in the field
Open Access
- 8 May 2016
- journal article
- research article
- Published by Springer Nature in Trials
- Vol. 17 (1) , 239
Abstract
This study was carried out as a prospective clinical field study with the aim of evaluating the clinical performance of Equia Fil® with a nanofilled resin coating and the conventional Fuji IX GP® fast with an LC coating according to the World Dental Federation (FDI) restoration material evaluation criteria. The clinical performance of Equia Fil® and Fuji IX GP® fast was evaluated on permanent posterior teeth of 643 adult patients aged between 20 to 80 years old in randomly selected clinics across Germany. Occlusal cavities in posterior permanent teeth were restored with Equia Fil® with a nanofilled, light-cured resin coating (n = 515) and Fuji IX GP® fast with an LC coating (n = 486). Direct clinical assessment as well as photographic assessment and assessment of stone casts of the restorations were made at 1 year, 2 years, 3 years, and 4 years. In 4 years, a total of 1001 fillings from both materials were placed by 111 dentists in 643 patients. Random slope models showed that the Equia filling system had overall lower odds of obtaining a delta event (material needs replacement) in comparison to Fuji IX GP® fast with an LC coating within all models. In both materials, filling size/surface was the most important component affecting the clinical performance of the materials. When measuring the odds of obtaining a delta event (material needs replacement), the odds ratios jumped to approximately 43 and 296 times for class II (two surfaces) and class II mesial-occlusal-distal (three surfaces) respectively in comparison to class I fillings. Both materials showed similar good overall performance in class I cavities; however, when including numbers from both class I and II fillings, the Equia system with a nanofilled resin coating showed better overall performance with fewer failures in all the follow-up intervals. Nonetheless, the percentage of unsatisfactory to poor fillings according to the FDI criteria was relatively high in two-surface class II fillings and higher in three-surface class II fillings for both materials. Deutsches Register Klinischer Studien (German Clinical Trials Register): DRKS00004220. ( www.germanctr.de ). Registration date: 6 Sept 2012.Keywords
This publication has 26 references indexed in Scilit:
- Clinical performance of a new glass ionomer based restoration system: A retrospective cohort studyDental Materials, 2011
- Fracture toughness of dental restorative materialsClinical Oral Investigations, 2011
- FDI World Dental Federation: clinical criteria for the evaluation of direct and indirect restorations—update and clinical examplesClinical Oral Investigations, 2010
- Clinical Performance of Viscous Glass Ionomer Cement in Posterior Cavities over Two YearsInternational Journal of Dentistry, 2009
- Clinical performance of reinforced glass ionomer restorations placed in UK dental practicesBritish Dental Journal, 2007
- In vitro toothbrush-dentifrice abrasion of resin-modified glass ionomersDental Materials, 1997
- Effect of surface coatings on flexural properties of glass ionomersEuropean Journal of Oral Sciences, 1996
- Early and Long-term Wear of Conventional and Resin-modified Glass IonomersJournal of Dental Research, 1996
- In vitro abrasion resistance and hardness of glass-ionomer cementsDental Materials, 1991
- GOOD CLINICAL PRACTICE IN CLINICAL RESEARCHThe Lancet, 1989