GyroLock: Stabilizing the Heart With Control Moment Gyroscope (CMG)—From Concept to First In Vivo Assessments
- 1 August 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 28 (4) , 942-954
Abstract
We present herein an original solution to actively stabilize the epicardium in the context of beating-heart coronary artery bypass grafting. Our solution uses a control moment gyroscope to generate the compensation torque and an accelerometer for sensing. This approach makes the designed system completely independent from the stabilizing instrument, as well as independent from any external measurement. We compare two control approaches in a simulation: The first one uses a Kalman filter with a harmonic disturbance model, and the second one uses an adaptive algorithm. Results highlight the superiority of the adaptive control for our application. The first in vivo assessments are presented, showing the efficiency of the principle under real conditions. Using only accelerometric measurements, targeted cardiac motion harmonics are reduced on the order of 68%. With an optical sensor, the reduction exceeds 90%. This constitutes an improvement compared with prior solutions, despite the presence of nonnegligible uncertainties and distant sensing.Keywords
This publication has 41 references indexed in Scilit:
- Three-dimensional Motion Tracking for Beating Heart Surgery Using a Thin-plate Spline Deformable ModelThe International Journal of Robotics Research, 2009
- Motion Prediction for Computer-Assisted Beating Heart SurgeryIEEE Transactions on Biomedical Engineering, 2009
- Robotic Motion Compensation for Beating Heart Intracardiac SurgeryThe International Journal of Robotics Research, 2009
- A Kalman Filter Design Based on the Performance/Robustness TradeoffIEEE Transactions on Automatic Control, 2009
- Methodological Insights for Online Estimation of Induction Motor ParametersIEEE Transactions on Control Systems Technology, 2008
- An Active Motion Compensation Instrument for Beating Heart Mitral Valve Surgery2007
- Resting Heart Rate in Cardiovascular DiseaseJACC, 2007
- Active filtering of physiological motion in robotized surgery using predictive controlIEEE Transactions on Robotics, 2005
- Limitations for manual and telemanipulator-assisted motion tracking—implications for endoscopic beating-heart surgeryThe Annals of Thoracic Surgery, 2003
- Adaptive algorithms for the rejection of sinusoidal disturbances with unknown frequencyAutomatica, 1997