Full Field Image Reconstruction Is Suitable for High-Pitch Dual-Source Computed Tomography
Authors:
- Andreas H. MahnkenAMAndreas H. Mahnken
- Thomas AllmendingerTAThomas Allmendinger
- Martin SedlmairMSMartin Sedlmair
- Miriam TammMTMiriam Tamm
- Sebastian D. ReinartzSRSebastian D. Reinartz
- Thomas FlohrTFThomas Flohr
- 1 November 2012
- journal article
- case report
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 47 (11) , 642-648
Abstract
The field of view (FOV) in high-pitch dual-source computed tomography (DSCT) is limited by the size of the second detector. The goal of this study was to develop and evaluate a full FOV image reconstruction technique for high-pitch DSCT. For reconstruction beyond the FOV of the second detector, raw data of the second system were extended to the full dimensions of the first system, using the partly existing data of the first system in combination with a very smooth transition weight function. During the weighted filtered backprojection, the data of the second system were applied with an additional weighting factor. This method was tested for different pitch values from 1.5 to 3.5 on a simulated phantom and on 25 high-pitch DSCT data sets acquired at pitch values of 1.6, 2.0, 2.5, 2.8, and 3.0. Images were reconstructed with FOV sizes of 260 × 260 and 500 × 500 mm. Image quality was assessed by 2 radiologists using a 5-point Likert scale and analyzed with repeated-measure analysis of variance. In phantom and patient data, full FOV image quality depended on pitch. Where complete projection data from both tube-detector systems were available, image quality was unaffected by pitch changes. Full FOV image quality was not compromised at pitch values of 1.6 and remained fully diagnostic up to a pitch of 2.0. At higher pitch values, there was an increasing difference in image quality between limited and full FOV images (P = 0.0097). With this new image reconstruction technique, full FOV image reconstruction can be used up to a pitch of 2.0.Keywords
This publication has 18 references indexed in Scilit:
- Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image qualityEuropean Journal of Radiology, 2012
- High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experienceEuropean Radiology, 2011
- Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition modeEuropean Radiology, 2011
- Use of High-Pitch Dual-Source Computed Tomography of the Abdomen and Pelvis to Markedly Reduce Scan TimeJournal of Computer Assisted Tomography, 2011
- High-Pitch Spiral Computed TomographyInvestigative Radiology, 2011
- Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft PatencyInvestigative Radiology, 2010
- Saving Dose in Triple-Rule-Out Computed Tomography Examination Using a High-Pitch Dual Spiral TechniqueInvestigative Radiology, 2010
- Dual‐source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image qualityMedical Physics, 2009
- Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patientsEuropean Radiology, 2009
- Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisitionEuropean Heart Journal, 2009