Abstract
Study Design. The effect of long, rigid fixation on adjacent level hypermobility was investigated in a human cadaver model with and without a transitional posterior dynamic stabilization (PDS) device placed at the last caudal level. Objective. To evaluate if PDS devices are useful in the setting of spinal deformities to restore increased adjacent level motions, which occur in long constructs. The hypothesis is that load-sharing benefits of these devices will be most suitable in long constructs and may reduce thoracolumbar junctional effects. The PDS device evaluated has a compressive spacer and flexion-dampening bumper. Summary of Background Data. Mechanical factors such as excessive mobility, increased disc height due to instrumentation, and abnormal loading are thought to accentuate distal level problems, which occur in extended instrumentation. Specifically adjacent level degeneration and distal junctional kyphosis are known to occur in these cases. Methods. Seven cadaver spines were tested from T7 to L3. Long instrumentation was applied in 2 rigid groups, R1: Rigid (T8–L2) and R2: Rigid (T8–L1), and PDS to the last caudal level of each, RP1: Rigid (T8–L1) + PDS (L1–L2), and RP2: Rigid (T8–T12) + PDS (T12–L1). Range of motion was evaluated at surgical and distal adjacent levels after displacement controlled loading in a spine tester. Results. Distal adjacent level motion was increased after 5- and 6-level rigid fixation in flexion-extension, lateral bending, and axial rotation. Most of the increases were seen in axial rotation and lateral bending. Replacing the last caudal instrumented level with the PDS test device was able to alleviate hypermobile conditions of the adjacent noninstrumented level, closer to intact (24%, 12% reduction in RP2, RP1, respectively). Conclusion. Reduction of hypermobility caused by extended arthrodesis may represent a new and ideally suited function for PDS devices. Mechanically, the devices were seen to kinematically restore abnormal distal motion, especially with placement of the PDS at the thoracolumbar junction.Keywords
This publication has 19 references indexed in Scilit:
- Evaluation of Proximal Junctional Kyphosis in Adolescent Idiopathic Scoliosis Following Pedicle Screw, Hook, or Hybrid InstrumentationSpine, 2010
- Adjacent Segment Disease After Instrumented Fusion for Idiopathic ScoliosisJournal of Spinal Disorders & Techniques, 2009
- Incidence and Risk Factors for Proximal and Distal Junctional Kyphosis Following Surgical Treatment for Scheuermann KyphosisSpine, 2009
- Biomechanical Analysis of a Disc Prosthesis Distal to a Scoliosis ModelSpine, 2009
- Distal Junctional Kyphosis of Adolescent Idiopathic Thoracic Curves Following Anterior or Posterior Instrumented Fusion: Incidence, Risk Factors, and PreventionSpine, 2006
- Proximal Junctional Kyphosis in Adolescent Idiopathic Scoliosis Following Segmental Posterior Spinal Instrumentation and FusionSpine, 2005
- Comparative Analysis of Pedicle Screw Versus Hook Instrumentation in Posterior Spinal Fusion of Adolescent Idiopathic ScoliosisSpine, 2004
- ADJACENT SEGMENT DEGENERATION IN THE LUMBAR SPINEJournal of Bone and Joint Surgery, 2004
- Magnetic Resonance Imaging Assessment of Disc Degeneration 10 Years After Anterior Lumbar Interbody FusionSpine, 1995
- The Effect on the Lumbosacral Spine of Long Spinal Fusion for Idiopathic ScoliosisSpine, 1987