Review of experiments investigating transformer insulation condition on bubble inception temperature
Authors:
- 1 May 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 863-866
Abstract
The power transformer is a vital asset within the electrical network and infrastructure. Hence, failures can cause large financial and societal impacts. One means of transformer failure occurs when the transformer is operated at excessively high load, for instance due to high user demand for electricity, or through circumstances such as failure of a parallel transformer. The overload increases the transformer operating temperature. This may generate bubbles within the transformer, which has been identified as one of the failure mechanisms. Better understanding of the scenarios where this may occur can arm the transformer operator to mitigate bubbling events, thus preventing premature transformer failures. Current knowledge regarding bubbling caused by loading and temperature is still not fully understood. Although a few studies have looked into this phenomenon, they have not yet determined a consistent or complete set of results for temperature versus condition or load. Within this study, the different experimental methods and designs used by different researchers are compared in order to draw out the reasons for variance between them, as well as to inform future studies as to the importance of these features to the temperature results.Keywords
This publication has 14 references indexed in Scilit:
- Investigation on bubbling phenomenon in oil-paper insulationIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- Methodology to assess distribution transformer thermal capacity for uptake of low carbon technologiesIET Generation, Transmission & Distribution, 2017
- A comparison of the formation of bubbles and water droplets in vegetable and mineral oil impregnated transformer paperIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- A comparison of bubble evolution temperature in aramid and cellulose paper2013
- Evolution of bubbles in oil–paper insulation influenced by material quality and ageingIET Electric Power Applications, 2011
- Asset-Management of Transformers Based on Condition Monitoring and Standard Diagnosis [Feature Article]IEEE Electrical Insulation Magazine, 2008
- Aging Study and Lifetime Estimation of Transformer Mineral OilAmerican Journal of Engineering and Applied Sciences, 2008
- Gas Bubble Studies and Impulse Tests on Distribution Transformers During Loading Above Nameplate RatingIEEE Transactions on Power Apparatus and Systems, 1983
- Bubble Formation in Power Transformer Windings at Overload TemperaturesIEEE Transactions on Power Apparatus and Systems, 1979
- Gas Bubbles In Distribution TransformersIEEE Transactions on Power Apparatus and Systems, 1977