Quantification of Hepatitis B Virus (HBV) DNA with a TaqMan HBV Analyte-Specific Reagent following Sample Processing with the MagNA Pure LC Instrument
- 1 April 2006
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 44 (4) , 1490-4
Abstract
TaqMan hepatitis B virus (HBV) analyte-specific reagent (ASR; Roche Molecular Systems, Inc., Branchburg, NJ) is designed for the quantification of HBV DNA in serum or plasma. The performance characteristics of TaqMan HBV ASR following automated sample processing with the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, IN) were evaluated in this study. Analytical sensitivity and precision were assessed with commercially available HBV standards, while clinical serum specimens from HBsAg-seropositive patients and healthy blood donors were used to determine clinical sensitivity, specificity, and correlation with other commercially available assays. Analytical studies yielded a limit of detection of 2.4 IU/ml, with good linearity and correlation ( R 2 = 0.9958) with expected HBV DNA titers over a wide range (6.0 × 10 0 to 2.1 × 10 8 IU/ml). Clinical sensitivity and specificity of the assay combined with automated sample processing were both 100%. Comparison of TaqMan HBV ASR and VERSANT HBV DNA 3.0 assay (bDNA; Bayer HealthCare LLC, Tarrytown, NY) results among clinical specimens yielded good correlation ( R 2 = 0.9237), with a mean difference in titer of −0.213 log 10 IU/ml (95% confidence interval, −0.678 to 1.10 log 10 IU/ml). The overall test failure rate was 2.0% among 204 clinical serum specimens tested. Total time required for MP sample processing and automated postelution handling of 24 samples was 224 min, with 57 min of actual hands-on time. MP is a reliable, labor-saving platform suitable for use with TaqMan HBV ASR, providing sensitive and accurate quantification of HBV DNA levels over a range of 8 log 10 IU/ml.Keywords
This publication has 15 references indexed in Scilit:
- Hepatitis B Virus Genotype and DNA Level and Hepatocellular Carcinoma: A Prospective Study in MenJNCI: Journal of the National Cancer Institute, 2005
- Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC InstrumentJournal of Clinical Microbiology, 2005
- Performance Characteristics of a Quantitative TaqMan Hepatitis C Virus RNA Analyte-Specific ReagentJournal of Clinical Microbiology, 2004
- Real time TaqMan PCR detection and quantitation of HBV genotypes A–G with the use of an internal quantitation standardJournal of Clinical Virology, 2004
- Multicenter Evaluation of the VERSANT Hepatitis B Virus DNA 3.0 AssayJournal of Clinical Microbiology, 2004
- Serum Hbv Dna As A Marker of Efficacy During Therapy for Chronic Hbv Infection: Analysis and Review of the LiteratureHepatology, 2003
- Management of hepatitis B: 2000—Summary of a workshopGastroenterology, 2001
- Monitoring the Virus Load Can Predict the Emergence of Drug‐Resistant Hepatitis B Virus Strains in Renal Transplantation Patients during Lamivudine TherapyThe Journal of Infectious Diseases, 2000
- Hepatitis B Virus InfectionNew England Journal of Medicine, 1997
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986