Individually Addressable Gel-Integrated Voltammetric Microelectrode Array for High-Resolution Measurement of Concentration Profiles at Interfaces
Authors:
- 14 April 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (10) , 2273-2281
Abstract
The application of a novel voltammetric probe, based on an individually addressable gel-integrated microelectrode array (IA-GIME), for real-time, high-spatial resolution concentration profile measurements at interfaces is described. Reliability and validity of steep metal concentration gradients obtained with this novel system have been demonstrated by performing systematic tests at well-controlled liquid−liquid and liquid−solid interfaces. The liquid−liquid interface was formed by two layers of aqueous solutions with different components; only one layer contained trace metal ions (Pb(II) and Cd(II)); the individually addressable microelectrode array was placed at the interface of the liquid−liquid system; the concentration profiles were recorded as function of time; and the effective diffusion coefficients were calculated. The liquid−“solid” interface was formed from an aqueous solution layer overlying a bed of silica particles saturated with an aqueous solution. The sensor array has been used to monitor the diffusion processes of Tl(I) or Pb(II) from the liquid phase to the “solid” phase. The influences of porosity, geometry of the porous media, and complexation between metal ion and silica, on the diffusion processes, have been studied. All these results show that correct diffusion profiles of metal ions at interfaces can be obtained with 200-μm resolution with the IA-GIME. They also demonstrate that, for measurements in “solid” phase, the aforementioned factors must be considered carefully for correct calibration of any electrodes and the gel-integrated microelectrodes are unique tools to enable calibration of the sensors with synthetic solutions.Keywords
This publication has 41 references indexed in Scilit:
- Automated Electrochemical Analysis with Combinatorial Electrode ArraysAnalytical Chemistry, 1999
- An amperometric microsensor array with 1024 individually addressable elements for two-dimensional concentration mappingSensors and Actuators B: Chemical, 1995
- Development of a Gold Amalgam Voltammetric Microelectrode for the Determination of Dissolved Fe, Mn, O2, and S(-II) in Porewaters of Marine and Freshwater SedimentsEnvironmental Science & Technology, 1995
- Performance Characteristics of Gel Probes Used For Measuring the Chemistry of Pore WatersEnvironmental Science & Technology, 1994
- Array of individually addressable microelectrodesSensors and Actuators B: Chemical, 1994
- Microelectronic and nanoelectronic interfacing techniques for biological systemsSensors and Actuators B: Chemical, 1992
- Denitrification and oxygen respiration in biofilms studied with a microsensor for nitrous oxide and oxygenMicrobial Ecology, 1990
- In situ collection of diagenetic iron and manganese oxyhydroxides from natural sedimentsNature, 1989
- EC array sensor concepts and dataLife Sciences, 1987
- Static and kinetic studies of adsorption-desorption of metal ions on a .gamma.-alumina surface. 1. Static study of adsorption-desorptionThe Journal of Physical Chemistry, 1984