Association Between Circular Stapler Diameter and Stricture Rates Following Gastrointestinal Anastomosis: Systematic Review and Meta‐analysis
Authors:
- 9 April 2018
- journal article
- review article
- Published by Wiley in World Journal of Surgery
- Vol. 42 (10) , 3097-3105
Abstract
Background: Stricture is a common complication of gastrointestinal (GI) anastomoses, associated with impaired quality of life, risk of malnutrition, and further interventions. This systematic review and meta‐analysis aimed to determine the association between circular stapler diameter and anastomotic stricture rates throughout the GI tract.Methods: A systematic literature search of EMBASE, MEDLINE and Cochrane Library was performed. The primary outcome was the rate of radiologically or endoscopically confirmed anastomotic stricture. Pooled odds ratios (OR) were calculated using random‐effects models to determine the effect of circular stapler diameter on stricture rates in different regions of the GI tract.Results: Twenty‐one studies were identified: seven oesophageal, twelve gastric, and three lower GI. Smaller stapler sizes were strongly associated with higher anastomotic stricture rates throughout the GI tract. The oesophageal anastomosis studies showed; 21 versus 25 mm circular stapler: OR 4.39 ([95% CI 2.12, 9.07];P < 0.0001); 25 versus 28/29 mm circular stapler: OR 1.71 ([95% CI 1.15, 2.53];P < 0.008). Gastric studies showed; 21 versus 25 mm circular stapler: OR 3.12 ([95% CI 2.23, 4.36];P < 0.00001); 25 versus 28/29 mm circular stapler: OR 7.67 ([95% CI 1.86, 31.57];P < 0.005). Few lower GI studies were identified, though a similar trend was found: 25 versus 28/29 mm circular stapler: pooled OR 2.61 ([95% CI 0.82, 8.29];P = 0.100).Conclusions: The use of larger circular stapler sizes is strongly associated with reduced risk of anastomotic stricture in the upper GI tract, though data from lower GI joins are limited.Keywords
This publication has 44 references indexed in Scilit:
- Stenosis after use of the double-stapling technique for reconstruction after laparoscopy-assisted total gastrectomySurgical Endoscopy, 2013
- Successful management of gastrojejunal strictures after gastric bypass: is timing important?Surgery for Obesity and Related Diseases, 2012
- Influence of the Stapler Size Used in Esophagojejunostomy Anastomosis: Anastomotic Leak and Strictures After Total GastrectomyTurkiye Klinikleri Journal of Medical Sciences, 2012
- Impact of gastrojejunostomy diameter on long-term weight loss following laparoscopic gastric bypass: a follow-up studySurgical Endoscopy, 2010
- Strukturrate nach zirkulärer vs. lineal gestapelter Gastrojejunostomie bei laparoskopischem MagenbypassEuropean Surgery, 2006
- The impact of circular stapler diameter on the incidence of gastrojejunostomy stenosis and weight loss following laparoscopic Roux-en-Y gastric bypassSurgical Endoscopy, 2006
- Measuring inconsistency in meta-analysesBMJ, 2003
- Assessing the quality of reports of randomized clinical trials: Is blinding necessary?Controlled Clinical Trials, 1996
- Stricture at the pouch-anal anastomosis after restorative proctocolectomyDiseases of the Colon & Rectum, 1994
- Gastrointestinal Anastomoses Factors Affecting Early ComplicationsAnnals of Surgery, 1987