Comparative study of autodyne and heterodyne laser interferometry for imaging
Authors:
- 22 October 2010
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 27 (11) , 2450-2458
Abstract
For given laser output power, object under investigation, and photodiode noise level, we have theoretically compared the signal-to-noise ratios of a heterodyne scanning imager based on a Michelson interferometer and of an autodyne setup based on the laser optical feedback imaging (LOFI) technique. In both cases, the image is obtained point by point. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity (i.e., directly on the detector), while in the autodyne configuration, the wave beating takes place inside the laser cavity and therefore is indirectly detected. In the autodyne configuration, where the laser relaxation oscillations play a leading role, we have compared one-dimensional scans obtained by numerical simulations with different lasers' dynamical parameters. Finally, we have determined the best laser for LOFI applications and the experimental conditions for which the LOFI detection setup (autodyne interferometer) is competitive compared to a heterodyne interferometer.Keywords
All Related Versions
This publication has 22 references indexed in Scilit:
- A heterodyne interferometer for angle metrologyReview of Scientific Instruments, 2010
- Photothermal optical coherence tomography in ex vivo human breast tissues using gold nanoshellsOptics Letters, 2010
- High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probeOptics Express, 2010
- Quantitative cerebral blood flow with Optical Coherence TomographyOptics Express, 2010
- Long-term stabilization of a heterodyne metrology interferometer down to a noise level of 20 pm over an hourApplied Optics, 2009
- Real-time nanometer-vibration measurement with a self-mixing microchip solid-state laserOptics Letters, 2002
- Comparative study of confocal and heterodyne microscopy for imaging through scattering mediaJournal of the Optical Society of America A, 1996
- Ultrahighly sensitive laser-Doppler velocity meter with a diode-pumped Nd:YVO4 microchip laserReview of Scientific Instruments, 1995
- Optical coherence microscopy in scattering mediaOptics Letters, 1994
- Highly Sensitive Measurement of Doppler-Shift with a Microchip Solid-State LaserJapanese Journal of Applied Physics, 1992