Atomic Resolution Imaging on Si(100)2×1 and Si(100)2×1:H Surfaces with Noncontact Atomic Force Microscopy

Authors:
  • KYKousuke Yokoyama
    Kousuke Yokoyama
  • TOTaketoshi Ochi
    Taketoshi Ochi
  • AYAkira Yoshimoto
    Akira Yoshimoto
  • YSYasuhiro Sugawara
    Yasuhiro Sugawara
  • SMSeizo Morita
    Seizo Morita

Abstract
We investigate the difference in atomic resolution images between the Si(100)2×1 reconstructed surface with a dangling bond and the Si(100)2×1:H monohydride surface without a dangling bond using noncontact atomic force microscopy. On the Si(100)2×1 surface, the distance between bright spots is 3.2 ±0.1 Å, which is larger than that between silicon atoms. On the Si(100)2×1:H surface, the distance between bright spots is 3.5 ±0.1 Å, which is in good agreement with that between hydrogen atoms. For the first time, individual hydrogen atoms are resolved. This means that the distance between measured bright spots forming dimers is increased by the hydrogen termination.

This publication has 28 references indexed in Scilit: