Physiology‐Based Stretchable Electronics Design Method for Accurate Surface Electromyography Evaluation
Authors:
Open Access
- 1 May 2021
- journal article
- research article
- Published by Wiley in Advanced Science
- Vol. 8 (13) , 2004987
Abstract
Stretchable electronics‐based surface electromyography (sEMG) evaluation devices are expected to play a big role in clinical diagnosis. However, the stability and quality of the signals collected by existing stretchable electronics are too poor, especially when muscle movement is involved, making them inappropriate for high standard clinical diagnosis. Here, a physiology‐based design method for stretchable electronics and a novel airbag‐type stretchable electrode array (ASEA) device for assessment of the complex female pelvic floor muscle (PFM) is proposed. Clinical trials show that the ASEA device is able to provide stable contact interface and multi‐channel accurate data acquisition. The stability and quality of the sEMG signal are much better than those obtained by the existing stretchable electronics‐based PFM electrode devices. Furthermore, a muscle‐unit evaluation method (MUEM) to assess the PFM complex state is proposed, especially its cross‐interaction between muscles. Clinical trials show that MUEM can accurately and comprehensively assess PFM state and the correlations between main muscles, which unveils the mechanisms of some special muscle states that are not possible using traditional methods. This proof of concept research holds the promise for the development of new diagnostic strategies for muscle pathological research, and has the potential for clinical application and general implication.Keywords
This publication has 51 references indexed in Scilit:
- Mechanics of stretchable electronics on balloon catheter under extreme deformationInternational Journal of Solids and Structures, 2014
- State of the art review: Intravaginal probes for recording electromyography from the pelvic floor musclesNeurourology and Urodynamics, 2013
- Intraclass correlation coefficientBMJ, 2013
- Reliability and differentiation of pelvic floor muscle electromyography measurements in healthy volunteers using a new device: The multiple array probe leiden (MAPLe)Neurourology and Urodynamics, 2012
- Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapyNature Materials, 2011
- Modeling of creep deformation and its effect on stress distribution in multilayer systems under residual stress and external bendingThin Solid Films, 2009
- Prevalence of Symptomatic Pelvic Floor Disorders in US WomenJAMA, 2008
- Biometry of the pubovisceral muscle and levator hiatus by three‐dimensional pelvic floor ultrasoundUltrasound in Obstetrics & Gynecology, 2005
- Pelvic Floor Muscle Behavior During Valsalva Leak Point Pressure Measurement in Males and Females Affected by Stress Urinary IncontinenceJournal of Urology, 2003
- The prevalence of pelvic floor disorders and their relationship to gender, age, parity and mode of deliveryBJOG: An International Journal of Obstetrics & Gynaecology, 2000