Healing changes in clear corneal cataract incisions evaluated using Fourier-domain optical coherence tomography
Authors:
- Lena DixitLDLena Dixit
- Mitchell P. WeikertMWMitchell P. Weikert
- Richard B. JenkinsRJRichard B. Jenkins
- Douglas D. KochDKDouglas D. Koch
- 1 April 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (4) , 660-665
Abstract
To evaluate the long-term wound-healing changes in clear corneal cataract incisions using Fourier-domain optical coherence tomography (OCT). Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Multiple OCT images were obtained in consecutive eyes that had phacoemulsification 1 day to 180 months previously. The incision midpoint was measured with OCT. The presence of Descemet membrane detachment, posterior wound gape, and posterior wound retraction was assessed. The depth of wound retraction along the incision and the radial length of the incision were measured. The percentage of wound retraction relative to radial incision length was calculated. Descemet membrane detachment was present in 37.1% of eyes 1 day postoperatively and in 4.5% of eyes at 1 to 3 months (P=.005); it was absent after 3 months. Posterior wound gape appeared in 85.7% of eyes at 1 day and in 31.8% at 1 to 3 months (P<.001); it was absent after 3 months. Posterior wound retraction appeared in 33.3% of eyes at 2 to 3 weeks, in 75.0% at 1 to 3 years, and in 90.5% after 3 years (P<.001). The mean wound retraction was 120 μm ± 46 (SD) (range 24 to 225 μm), which was 7.5% ± 3.1% (range 2.0% to 13.4%) of the radial incision length. Descemet membrane detachment and posterior wound gape appeared in the early postoperative period and persisted for up to 3 months, whereas posterior wound retraction developed later and was present in more than 90% of eyes after 3 years, indicating long-term wound remodeling.Keywords
This publication has 12 references indexed in Scilit:
- OCT-Documented Incision Features and Natural History of Clear Corneal Incisions Used for Bimanual Microincision Cataract SurgeryCornea, 2011
- Wound Architecture of Clear Corneal Incision With or Without Stromal Hydration Observed With 3-Dimensional Optical Coherence TomographyAmerican Journal of Ophthalmology, 2011
- Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgeryJournal of Cataract & Refractive Surgery, 2011
- Usefulness of Anterior Segment Optical Coherence Tomography in Descemet Membrane DetachmentEuropean Journal of Ophthalmology, 2009
- In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomographyJournal of Cataract & Refractive Surgery, 2009
- Three-Dimensional Spectral Domain Optical Coherence Tomography of a Clear Corneal Cataract IncisionOphthalmic Surgery, Lasers and Imaging Retina, 2008
- Dynamics of Small-incision Clear Cornea Wounds After Phacoemulsification Surgery Using Optical Coherence Tomography in the Early Postoperative PeriodJournal of Refractive Surgery, 2008
- Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2007
- Profile of clear corneal cataract incisions demonstrated by ocular coherence tomographyJournal of Cataract & Refractive Surgery, 2007
- In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2006