The Effect of Optical Zone Decentration on Lower- and Higher-Order Aberrations after Photorefractive Keratectomy in a Cat Model
Authors:
Open Access
- 1 December 2007
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 48 (12) , 5806-5814
Abstract
Purpose. To simulate the effects of decentration on lower- and higher-order aberrations (LOAs and HOAs) and optical quality, by using measured wavefront error (WFE) data from a cat photorefractive keratectomy (PRK) model. methods. WFE differences were obtained from five cats’ eyes 19 ±7 weeks after spherical myopic PRK for −6 D (three eyes) and −10 D (two eyes). Ablation-centered WFEs were computed for a 9.0 mm pupil. A computer model was used to simulate decentration of a 6-mm subaperture in 100-μm steps over a circular area of 3000 μm diameter, relative to the measured WFE difference. Changes in LOA, HOA, and image quality (visual Strehl ratio based on the optical transfer function; VSOTF) were computed for simulated decentrations over 3.5 and 6.0 mm. results. Decentration resulted in undercorrection of sphere and induction of astigmatism; among the HOAs, decentration mainly induced coma. Decentration effects were distributed asymmetrically. Decentrations >1000 μm led to an undercorrection of sphere and cylinder of >0.5 D. Computational simulation of LOA/HOA interaction did not alter threshold values. For image quality (decrease of best-corrected VSOTF by >0.2 log units), the corresponding thresholds were lower. The amount of spherical aberration induced by the centered treatment significantly influenced the decentration tolerance of LOAs and log best corrected VSOTF. conclusions. Modeling decentration with real WFE changes showed irregularities of decentration effects for rotationally symmetric treatments. The main aberrations induced by decentration were defocus, astigmatism, and coma. Treatments that induced more spherical aberration were less tolerant of decentration.Keywords
This publication has 42 references indexed in Scilit:
- Interaction between aberrations to improve or reduce visual performanceJournal of Cataract & Refractive Surgery, 2003
- Repeatability of Ocular Wavefront MeasurementOptometry and Vision Science, 2003
- Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablationJournal of Cataract & Refractive Surgery, 2003
- Higher-order wavefront aberrations induced by small ablation area and sub-clinical decentration in simulated corneal refractive surgery using a perturbed schematic eye modelSeminars in Ophthalmology, 2003
- Standards for Reporting the Optical Aberrations of EyesJournal of Refractive Surgery, 2002
- Aberration-sensing and Wavefront-guided Laser in situ Keratomileusis: Management of Decentered AblationJournal of Refractive Surgery, 2002
- Ablation profiles for wavefront-guided correction of myopia and primary spherical aberrationJournal of Cataract & Refractive Surgery, 2002
- Improvement in photorefractive corneal laser surgery results using an active eye-tracking systemJournal of Cataract & Refractive Surgery, 2001
- Effect of rotation and translation on the expected benefit of an ideal method to correct the eye’s higher-order aberrationsJournal of the Optical Society of America A, 2001
- Increased higher-order optical aberrations after laser refractive surgeryJournal of Cataract & Refractive Surgery, 2001