Errors during the preparation of drug infusions: a randomized controlled trial
Authors:
- R.M. AdapaRAR.M. Adapa
- V ManiVMV Mani
- L.J. MurrayLML.J. Murray
- B.A. DegnanBDB.A. Degnan
- A ErcoleAEA Ercole
- B CadmanBCB Cadman
- C.E. WilliamsCWC.E. Williams
- A.K. GuptaAGA.K. Gupta
- D.W. WheelerDWD.W. Wheeler
- 1 November 2012
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 109 (5) , 729-734
Abstract
We investigated the extent and frequency of dose errors and treatment delays made as a consequence of preparing drug infusions at the bedside, rather than using pre-filled syringes. Forty-eight nurses with critical care experience volunteered to take part in this randomized, blinded, controlled study conducted in the simulation centre of an urban hospital. They assisted in the management of a simulated patient with septic shock. Vasopressor infusions were prepared either by diluting concentrated drugs from ampoules or were provided in syringes pre-filled beforehand by an intensive care unit resident. The time taken for the infusion to be started and the final concentration of the drugs were measured. We also measured the concentration of infusions prepared by a pharmacist and a pharmaceutical company. Nurses took 156 s to start infusions when using pre-filled syringes compared with 276 s when preparing them de novo, a mean delay of 106 s [95% confidence interval (CI) 73-140 s, P<0.0001]. One infusion prepared from ampoules contained one-fifth of the expected concentration of epinephrine; another contained none at all. Medication errors were 17.0 times less likely when pre-filled syringes were used (95% CI 5.2-55.5), and infusions prepared by pharmacy and industry were significantly more likely to contain the expected concentration (P<0.001 for norepinephrine and P=0.001 for epinephrine). Providing drug infusions in syringes pre-filled by pharmacists or pharmaceutical companies would reduce medication errors and treatment delays, and improve patient safety. However, this approach would have substantial financial implications for healthcare providers, especially in less developed countries.Keywords
This publication has 18 references indexed in Scilit:
- Factors affecting the concentration of electrolyte infusions prepared from stock solutionsPostgraduate Medical Journal, 2010
- Protein adsorption and excipient effects on kinetic stability of silicone oil emulsionsJournal of Pharmaceutical Sciences, 2010
- The pathophysiology of medication errors: how and where they ariseBritish Journal of Clinical Pharmacology, 2009
- ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration—2008American Journal of Health-System Pharmacy, 2009
- Systematic evaluation of errors occurring during the preparation of intravenous medicationCanadian Medical Association Journal, 2008
- Decreasing errors in pediatric continuous intravenous infusions*Pediatric Critical Care Medicine, 2006
- Medication errors involving continuously infused medications in a surgical intensive care unitCritical Care Medicine, 2004
- Discrepancies between ordered and delivered concentrations of opiate infusions in critical careCritical Care Medicine, 2003
- Reengineering Intravenous Drug and Fluid Administration Processes in the Operating RoomAnesthesiology, 2002
- Random and systematic medication errors in routine clinical practice: a multicentre study of infusions, using acetylcysteine as an exampleBritish Journal of Clinical Pharmacology, 2001