Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms
- 21 September 2017
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 47 (2) , 195-201
Abstract
Objective Aim of this study was to assess the artifact reduction in patients with orthopedic hardware in the spine as provided by (1) metal-artifact-reduction algorithms (O-MAR) and (2) virtual monoenergetic images (MonoE) as provided by spectral detector CT (SDCT) compared to conventional iterative reconstruction (CI). Methods In all, 28 consecutive patients with orthopedic hardware in the spine who underwent SDCT-examinations were included. CI, O-MAR and MonoE (40–200 keV) images were reconstructed. Attenuation (HU) and noise (SD) were measured in order to calculate signal-to-noise ratio (SNR) of paravertebral muscle and spinal canal. Subjective image quality was assessed by two radiologists in terms of image quality and extent of artifact reduction. Results O-MAR and high-keV MonoE showed significant decrease of hypodense artifacts in terms of higher attenuation as compared to CI (CI vs O-MAR, 200 keV MonoE: −396.5HU vs. –115.2HU, −48.1HU; both p ≤ 0.001). Further, artifacts as depicted by noise were reduced in O-MAR and high-keV MonoE as compared to CI in (1) paravertebral muscle and (2) spinal canal—CI vs. O-MAR/200 keV: (1) 34.7 ± 19.0 HU vs. 26.4 ± 14.4 HU, p ≤ 0.05/27.4 ± 16.1, n.s.; (2) 103.4 ± 61.3 HU vs. 72.6 ± 62.6 HU/60.9 ± 40.1 HU, both p ≤ 0.001. Subjectively both O-MAR and high-keV images yielded an artifact reduction in up to 24/28 patients. Conclusion Both, O-MAR and high-keV MonoE reconstructions as provided by SDCT lead to objective and subjective artifact reduction, thus the combination of O-MAR and MonoE seems promising for further reduction.Keywords
This publication has 26 references indexed in Scilit:
- Artifacts at Cardiac CT: Physics and SolutionsRadioGraphics, 2016
- Metal artefact reduction in CT imaging of hip prostheses—an evaluation of commercial techniques provided by four vendorsBritish Journal of Radiology, 2015
- Dual energy CT: How well can pseudo‐monochromatic imaging reduce metal artifacts?Medical Physics, 2015
- Photon starvation artifacts of X-ray CT: their true cause and a solutionRadiological Physics and Technology, 2012
- Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolationEuropean Radiology, 2011
- Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the artEuropean Spine Journal, 2009
- Overcoming Artifacts from Metallic Orthopedic Implants at High-Field-Strength MR Imaging and Multi-detector CTRadioGraphics, 2007
- Multichannel CT: Evaluating the Spine in Postoperative Patients with Orthopedic HardwareRadioGraphics, 2006
- Multichannel CT Imaging of Orthopedic Hardware and ImplantsSeminars in Musculoskeletal Radiology, 2006
- The AAPM/RSNA physics tutorial for residents. X-ray interactions.RadioGraphics, 1998