Reconstructing Element-by-Element Dissipated Hysteretic Energy in Instrumented Buildings: Application to the Van Nuys Hotel Testbed
Preprint
Abstract
The authors propose a seismic monitoring framework for instrumented buildings that employs dissipated energy as a feature for damage detection and localization. The proposed framework employs a nonlinear model-based state observer, which combines a nonlinear finite element model of a building and global acceleration measurements to estimate the time history of seismic response at all degrees of freedom of the model. This includes displacements, element forces, and plastic deformations in all structural members. The estimated seismic response is then used to 1) estimate inter-story drifts and determine the post-earthquake re-occupancy classification of the building based on performance-based criteria, 2) compare the estimated demands with code-based capacity and reconstruct element-by-element demand-to-capacity ratios and 3) reconstruct element-level normalized energy dissipation and ductility. The outcome of this process is employed for the performance-based monitoring, damage detection, and localization in instrumented buildings. The proposed framework is validated using data from the Van Nuys hotel testbed; a seven-story reinforced concrete building instrumented by the California Strong Motion Instrumentation Program (Station 24386). The nonlinear state observer of the building is implemented using a distributed plasticity finite element model and seismic response measurements during the 1992 Big Bear and 1994 Northridge earthquakes. The performance and damage assessment results are compared with the post-earthquake damage inspection reports and photographic records. The results demonstrate the accuracy and capability of the proposed framework in the context of a real instrumented building that experienced significant localized structural damage.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Analytical fragility assessment using unscaled ground motion recordsEarthquake Engineering & Structural Dynamics, 2017
- Seismic FDD modal identification and monitoring of building properties from real strong-motion structural response signalsStructural Control and Health Monitoring, 2017
- A note on predetermined earthquake damage scenarios for structural health monitoringStructural Control and Health Monitoring, 2011
- Damage detection in instrumented structures without baseline modal parametersEngineering Structures, 2010
- Damage detection based on damping analysis of ambient vibration dataStructural Control and Health Monitoring, 2008
- Impulse response analysis of the Van Nuys 7-storey hotel during 11 earthquakes and earthquake damage detectionStructural Control and Health Monitoring, 2007
- Energy demands for seismic design against low‐cycle fatigueEarthquake Engineering & Structural Dynamics, 2006
- APPLICATION OF OFF-LINE AND ON-LINE IDENTIFICATION TECHNIQUES TO BUILDING SEISMIC RESPONSE DATAEarthquake Engineering & Structural Dynamics, 1996
- Evaluation of seismic energy in structuresEarthquake Engineering & Structural Dynamics, 1990
- Cumulative damage in steel structures subjected to earthquake ground motionsComputers & Structures, 1983