Quantification of the surface density of a fluorescent label with the optical microscope
Authors:
- 24 January 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 50 (1) , 90-96
Abstract
Fluorescence microscopy can offer unique advantages for biomaterials characterization. Like spectroscopy or radioactivity, it can be used to quantify specific binding to surfaces, but it can also assess surface homogeneity at the micron scale or detect protein aggregation. To fully utilize the potential of this technique, there must be a way to calibrate the microscope in terms of the moles of a fluorophore per unit area. The method we propose involves the following steps: fluorescent labeling of erythrocytes and quantification of the label by flow cytometry; flattening of fluorescent erythrocytes for microscopic observation; imaging and digital analysis to relate the gray level intensities to the fluorophore density; and using this procedure to characterize a different, more easily obtainable, standard. The latter can be a 50% solution of Na fluorescein that yields a highly reproducible and uniform fluorescence. Concentrated fluorescein solution can also be used to correct images for the spatial nonuniformity of illumination and detection (shading correction). By applying this method to study the binding of IgG and fibrinogen to glass or amidated glass, we showed that protein adsorption to glass may result in protein aggregation that may affect the biological activity of the adsorbed protein. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 50, 90–96, 2000.Keywords
This publication has 23 references indexed in Scilit:
- Adsorption of Complement, Cytokines, and Proteins by Different Dialysis Membrane Materials: Evaluation by Confocal Laser Scanning Fluorescence MicroscopyArtificial Organs, 1998
- Application of total internal reflection fluorescence microscopy to study cell adhesion to biomaterialsBiomaterials, 1998
- Shading correction and calibration in bacterial fluorescence measurement by image processing systemComputer Methods and Programs in Biomedicine, 1994
- Chapter 4 Multicolor Laser Scanning Confocal Immunofluorescence Microscopy: Practical Application and Limitations1993
- Preferential adsorption of dentin and bone acidic proteins on the (100) face of hydroxyapatite crystalsBiochimica et Biophysica Acta (BBA) - General Subjects, 1991
- Multiple spectral parameter imaging in quantitative fluorescence microscopy. I: Quantitativn of bead standardsComputerized Medical Imaging and Graphics, 1989
- Chapter 13 Basic Fluorescence Microscopy1988
- The study of fluorescent probes by quantitative video intensification microscopy (QVIM).Journal of Histochemistry & Cytochemistry, 1986
- Calibration by ellipsometry of the enzyme-linked immunosorbent assayJournal of Immunological Methods, 1985
- Quantitative immunofluorescenceHistochemistry and Cell Biology, 1971