Glucose Biosensor Based on the Microcantilever
Authors:
- 3 December 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (2) , 292-297
Abstract
Diagnosis and management of diabetes require quantitative and selective detection of blood glucose levels. We report a technique for micromechanical detection of biologically relevant glucose concentrations by immobilization of glucose oxidase (GOx) onto a microcantilever surface. Microfabricated cantilevers have traditionally found utility in atomic force microscope imaging. During the past decade, however, microcantilevers have been increasingly used as transducers in chemical-sensing systems. This paper describes the combination of this technology with enzyme specificity to construct a highly selective glucose biosensor. The enzyme-functionalized microcantilever undergoes bending due to a change in surface stress induced by the reaction between glucose in solution and the GOx immobilized on the cantilever surface. Experiments were carried out under flow conditions. The common interferences for glucose detection in other detection schemes have been tested and have shown to have no effect on the measurement of blood glucose level by this technique.Keywords
This publication has 15 references indexed in Scilit:
- Nanomechanical Effect of Enzymatic Manipulation of DNA on Microcantilever SurfacesLangmuir, 2002
- Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever arrayProceedings of the National Academy of Sciences, 2002
- Glucose biosensing using an enzyme-coated microcantileverApplied Physics Letters, 2002
- Complementary Metal Oxide Semiconductor Cantilever Arrays on a Single Chip: Mass-Sensitive Detection of Volatile Organic CompoundsAnalytical Chemistry, 2002
- Characterisation of an antibody coated microcantilever as a potential immuno-based biosensorBiosensors and Bioelectronics, 2002
- A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readoutSensors and Actuators B: Chemical, 2001
- Sol–gel based thermal biosensor for glucoseAnalytica Chimica Acta, 2001
- Development of the Implantable Glucose Sensor: What Are the Prospects and Why Is It Taking So Long?Diabetes, 1995
- Thermal and ambient-induced deflections of scanning force microscope cantileversApplied Physics Letters, 1994
- Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoringAnalytical Chemistry, 1991