Resuscitation Artifacts during Electroencephalography
Authors:
- 1 March 2002
- journal article
- research article
- Published by Taylor & Francis in American Journal of Electroneurodiagnostic Technology
- Vol. 42 (1) , 16-21
Abstract
Resuscitation artifacts during EEG have rarely been reported. We describe the artifact produced in the EEG by cardiopulmonary resuscitation (CPR) of four patients. In these patients, manual chest compression produced movement artifact that resembled periodic sharp waves or slow wave complexes (or both). Often this artifact was reflected in just a few electrodes, depending on the position of the patient's head at the time CPR was performed. For three patients, CPR was unsuccessful and the EEG showed complete absence of cerebral activity. The other patient recovered, and the EEG returned to baseline.Keywords
This publication has 6 references indexed in Scilit:
- EEG Monitoring in the Intensive Care Unit: Pitfalls and CaveatsJournal Of Clinical Neurophysiology, 1999
- Succinylcholine Induced Hyperkalemia and Cardiac Arrest: Death Related to an EEG StudyJournal Of Clinical Neurophysiology, 1999
- The EEG Changes during Cardiac Arrest: A Case ReportClinical Electroencephalography, 1998
- Electroencephalographic Monitoring of Cerebral Function During Asystole and Successful Cardiopulmonary ResuscitationAnesthesia & Analgesia, 1992
- EEG Monitoring During Cardiac Arrest and ResuscitationJAMA, 1980
- Atlas of Electroencephalography in Coma mid Cerebral DeathAnesthesiology, 1976