Wireless Synchronization of a Multi-Pinhole Small Animal SPECT Collimation Device With a Clinical Scanner
- 16 June 2009
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 56 (3) , 640-645
Abstract
A multi-pinhole collimation device for small animal single photon emission computed tomography (SPECT) uses the gamma camera detectors of a standard clinical SPECT scanner. The collimator and animal bed move independently of the detectors, and therefore their motions must be synchronized. One approach is manual triggering of the SPECT acquisition simultaneously with a programmed motion sequence for the device. However, some data blurring and loss of image quality result, and true electronic synchronization is preferred. An off-the-shelf digital gyroscope with integrated Bluetooth interface provides a wireless solution to device synchronization. The sensor attaches to the SPECT gantry and reports its rotational speed to a notebook computer controlling the device. Software processes the rotation data in real-time, averaging the signal and issuing triggers while compensating for baseline drift. Motion commands are sent to the collimation device with minimal delay, within approximately 0.5 second of the start of SPECT gantry rotation. Test scans of a point source demonstrate an increase in true counts and a reduction in background counts compared to manual synchronization. The wireless rotation sensor provides robust synchronization of the collimation device with the clinical SPECT scanner and enhances image quality.Keywords
This publication has 11 references indexed in Scilit:
- Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT–CT scannersPhysics in Medicine & Biology, 2008
- Small-Animal Preclinical Nuclear Medicine Instrumentation and MethodologySeminars in Nuclear Medicine, 2008
- Axial Resolution of Helical-Orbit Pinhole SPECT With Synchronized and Unsynchronized MotionIEEE Transactions on Nuclear Science, 2008
- Geometric characterization of multi-axis multi-pinhole SPECT.Medical Physics, 2007
- Detectors for Small-Animal SPECT I2007
- A robust visual tracking system for patient motion detection in SPECT: hardware solutionsIEEE Transactions on Nuclear Science, 2005
- Small animal SPECT and its place in the matrix of molecular imaging technologiesPhysics in Medicine & Biology, 2005
- A practical 3D tomographic method for correcting patient head motion in clinical SPECTIEEE Transactions on Nuclear Science, 1999
- Pinhole collimation for ultra-high-resolution, small-field-of-view SPECTPhysics in Medicine & Biology, 1994
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994