Determination of elemental compositions by gas chromatography/time‐of‐flight mass spectrometry using chemical and electron ionization
- 19 March 2010
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (8) , 1172-1180
Abstract
Many metabolomic applications use gas chromatography/mass spectrometry (GC/MS) under standard 70 eV electron ionization (EI) parameters. However, the abundance of molecular ions is often extremely low, impeding the calculation of elemental compositions for the identification of unknown compounds. On changing the beam‐steering voltage of the ion source, the relative abundances of molecular ions at 70 eV EI were increased up to ten‐fold for alkanes, fatty acid methyl esters and trimethylsilylated metabolites, concomitant with 2‐fold absolute increases in ion intensities. We have compared the abundance, mass accuracy and isotope ratio accuracy of molecular species in EI with those in chemical ionization (CI) with methane as reagent gas under high‐mass tuning. Thirty‐three peaks of a diverse set of trimethylsilylated metabolites were analyzed in triplicate, resulting in 342 ion species ([M+H] + , [M–CH 3 ] + for CI and [M] + . , [M–CH 3 ] + . for EI). On average, CI yielded 8‐fold more intense molecular species than EI. Using internal recalibration, average mass errors of 1.8 ± 1.6 m m/z units and isotope ratio errors of 2.3 ± 2.0% (A+1/A ratio) and 1.7 ± 1.8% (A+2/A ratio) were obtained. When constraining lists of calculated elemental compositions by chemical and heuristic rules using the Seven Golden Rules algorithm and PubChem queries, the correct formula was retrieved as top hit in 60% of the cases and within the top‐3 hits in 80% of the cases. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- FiehnLib: Mass Spectral and Retention Index Libraries for Metabolomics Based on Quadrupole and Time-of-Flight Gas Chromatography/Mass SpectrometryAnalytical Chemistry, 2009
- Extending the breadth of metabolite profiling by gas chromatography coupled to mass spectrometryTrAC Trends in Analytical Chemistry, 2008
- Quality control for plant metabolomics: reporting MSI‐compliant studiesThe Plant Journal, 2008
- Gas chromatography‐mass spectrometry with supersonic molecular beamsJournal of Mass Spectrometry, 2008
- Importance of the electron mass in the calculations of exact mass by time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2007
- Seven Golden Rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometryBMC Bioinformatics, 2007
- Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MSJournal of Experimental Botany, 2004
- Construction and application of a mass spectral and retention time index database generated from plant GC/EI-TOF-MS metabolite profilesPhytochemistry, 2003
- Bounds for molecular weights of organic compounds from low resolution mass spectraChemometrics and Intelligent Laboratory Systems, 1995
- Empirical pattern recognition/expert system for molecular weight estimation of low resolution mass spectraAnalytica Chimica Acta, 1994