Comparison of the in-vivo neural recording quality of floating and skull-fixed silicon probes
Authors:
- 1 May 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 158-161
Abstract
Silicon neural probes with sophisticated integrated CMOS-based electronics providing a large number of recording sites integrated along the slender probe shanks have become a driving force in neural engineering throughout the past decade. Using such neural probes in a chronic setting often requires to mechanically anchor them with respect to the skull. Any relative motion between brain and implant causes however tissue responses such as glial scarring, thereby the recordable neurons are shielded from the electrodes integrated on the probe, and the signal quality is decreased. In the current work, we present preliminary results obtained using a mechanically fixed and a floating silicon neural probe implanted into the cortex of a non-human primate. We demonstrate that the neural signal quality of the floating probe is superior to the fixed approach. Nonetheless, also the skull-fixed probe allowed to identify action potentials and stably record low frequency signals over the entire recording period.Keywords
This publication has 14 references indexed in Scilit:
- Time multiplexed active neural probe with 678 parallel recording sites2016
- Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sitesJournal of Neural Engineering, 2016
- Long Term Recordings with Immobile Silicon Probes in the Mouse CortexPLOS ONE, 2016
- Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cordJournal of Neural Engineering, 2015
- Application of floating silicon-based linear multielectrode arrays for acute recording of single neuron activity in awake behaving monkeysBiomedical Engineering / Biomedizinische Technik, 2014
- Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responsesJournal of Neural Engineering, 2013
- Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodiesJournal of Neural Engineering, 2011
- Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortexJournal of Neural Engineering, 2011
- Ultrathin Silicon Chips of Arbitrary Shape by Etching Before GrindingJournal of Microelectromechanical Systems, 2011
- Multichannel Micromanipulator and Chamber System for Recording Multineuronal Activity in Alert, Non-Human PrimatesJournal of Neurophysiology, 2007