Abstract
Purpose: To compare the accuracy of three intraocular lens (IOL) formulas in Chinese cataract patients with prior radial keratotomy (RK). Methods: Medical records of cataract patients with prior RK at Beijing Tongren Hospital were retrospectively analysed. The absolute error (AE) was calculated as the absolute difference between the actual postoperative spherical equivalent and the predicted spherical equivalent. The AE and percentages of eyes with AE within 0.5D, 1.0D, and 2.0D for three formulas [Barrett True-K, Holladay 1 (D–K), Haigis] were calculated and compared. Results: Forty-seven eyes of 28 cataract patients were included. The Median AE (MedAE) was significantly different among the three formulas (P < 0.001). The MedAE was lowest for the Barrett True-K formula (0.62), followed by the Haigis (0.76), and Holladay 1 (D–K) (1.16). The percentages of eyes with AE within 0.5D, and 1.0D were significantly different among the 3 formulas (P = 0.009, and P < 0.001). The Barrett True-K formula achieved the highest percentages (46.8%) of eyes with AE within 0.5D. Haigis achieved the highest percentages (70.21%) of eyes with AE within 1.0 D. Conclusions: Barrett True-K is the most accurate IOL power calculation formula among the 3 formulas and Haigis is an alternative choice. Considering the relatively lower accuracy of IOL formulas in cataract patients with prior RK, newer and more accurate IOL formulas are desirable.Keywords
Funding Information
- Beijing Hospitals Authority Clinical Medicine Development of Special Funding Support (XMLX202133)
- National Natural Science Foundation of China (82171037)
This publication has 27 references indexed in Scilit:
- Biometry in cataract surgeryCurrent Opinion in Ophthalmology, 2019
- Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomesJournal of Cataract & Refractive Surgery, 2017
- Outcomes of Phacoemulsification Using Different Size of Clear Corneal Incision in Eyes with Previous Radial KeratotomyPLOS ONE, 2016
- Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial KeratotomyInvestigative Ophthalmology & Visual Science, 2016
- High myopia and cataract surgeryCurrent Opinion in Ophthalmology, 2016
- Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive SurgeryOphthalmology, 2015
- Scheimpflug Camera Measurement of Anterior and Posterior Corneal Curvature in Eyes With Previous Radial KeratotomyJournal of Refractive Surgery, 2012
- Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomyClinical Ophthalmology, 2011
- Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power CalculatorJournal of Cataract & Refractive Surgery, 2010