Accuracy of Digital Pathologic Analysis vs Traditional Microscopy in the Interpretation of Melanocytic Lesions
Authors:
Open Access
- 1 October 2018
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Dermatology
- Vol. 154 (10) , 1159-1166
Abstract
Importance Use of digital whole-slide imaging (WSI) for dermatopathology in general has been noted to be similar to traditional microscopy (TM); however, concern has been noted that WSI is inferior for interpretation of melanocytic lesions. Since approximately 1 of every 4 skin biopsies is of a melanocytic lesion, the use of WSI requires verification before use in clinical practice. Objective To compare pathologists’ accuracy and reproducibility in diagnosing melanocytic lesions using Melanocytic Pathology Assessment Tool and Hierarchy for Diagnosis (MPATH-Dx) categories when analyzing by TM vs WSI. Design, Setting, and Participants A total of 87 pathologists in community-based and academic settings from 10 US states were randomized with stratification based on clinical experience to interpret in TM format 180 skin biopsy cases of melanocytic lesions, including 90 invasive melanoma, divided into 5 sets of 36 cases (phase 1). The pathologists were then randomized via stratified permuted block randomization with block size 2 to interpret cases in either TM (n = 46) or WSI format (n = 41), with each pathologist interpreting the same 36 cases on 2 separate occasions (phase 2). Diagnoses were categorized as MPATH-Dx categories I through V, with I indicating the least severe and V the most severe. Main Outcomes and Measures Accuracy with respect to a consensus reference diagnosis and the reproducibility of repeated interpretations of the same cases. Results Of the 87 pathologists in the study, 46% (40) were women and the mean (SD) age was 50.7 (10.2) years. Except for class III melanocytic lesions, the diagnostic categories showed no significant differences in diagnostic accuracy between TM and WSI interpretation. Discordance was lower among class III lesions for the TM interpretation arm (51%; 95% CI, 46%-57%) than for the WSI arm (61%; 95% CI, 53%-69%) (P = .05). This difference is likely to have clinical significance, because 6% of TM vs 11% of WSI class III lesions were interpreted as invasive melanoma. Reproducibility was similar between the traditional and digital formats overall (66.4%; 95% CI, 63.3%-69.3%; and 62.7%; 95% CI, 59.5%-65.7%, respectively), and for all classes, although class III showed a nonsignificant lower intraobserver agreement for digital. Significantly more mitotic figures were detected with TM compared with WSI: mean (SD) TM, 6.72 (2.89); WSI, 5.84 (2.56);P = .002. Conclusions and Relevance Interpretive accuracy for melanocytic lesions was similar for WSI and TM slides except for class III lesions. We found no clinically meaningful differences in reproducibility for any of the diagnostic classes.Keywords
This publication has 21 references indexed in Scilit:
- Diagnostic performance on briefly presented digital pathology imagesJournal of Pathology Informatics, 2015
- Validation of whole slide imaging for frozen section diagnosis in surgical pathologyJournal of Pathology Informatics, 2015
- Whole slide imaging for human epidermal growth factor receptor 2 immunohistochemistry interpretation: Accuracy, Precision, and reproducibility studies for digital manual and paired glass slide manual interpretationJournal of Pathology Informatics, 2015
- Implementation of large-scale routine diagnostics using whole slide imaging in Sweden: Digital pathology experiences 2006-2013Journal of Pathology Informatics, 2014
- The MPATH-Dx reporting schema for melanocytic proliferations and melanomaJournal of the American Academy of Dermatology, 2014
- Validating Whole Slide Imaging for Diagnostic Purposes in Pathology: Guideline from the College of American Pathologists Pathology and Laboratory Quality CenterArchives of Pathology & Laboratory Medicine, 2013
- Validation of Whole Slide Imaging for Primary Diagnosis in Surgical PathologyArchives of Pathology & Laboratory Medicine, 2013
- Digital Imaging in Pathology: Whole-Slide Imaging and BeyondAnnual Review of Pathology: Mechanisms of Disease, 2013
- Virtual microscopy using whole-slide imaging as an enabler for teledermatopathology: A paired consultant validation studyJournal of Pathology Informatics, 2012
- 2010 TNM Staging System for Cutaneous Melanoma…and BeyondAnnals of Surgical Oncology, 2010