Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometer and a rotating anode x-ray tube: theory and experiments
Authors:
- 2 June 2010
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (12) , 12960-12970
Abstract
X-ray differential phase contrast imaging methods, including projection imaging and the corresponding computed tomography (CT), have been implemented using a Talbot interferometer and either a synchrotron beam line or a low brilliance x-ray source generated by a stationary-anode x-ray tube. From small-angle scattering events which occur as an x-ray propagates through a medium, a signal intensity loss can be recorded and analyzed for an understanding of the micro-structures in an image object. This has been demonstrated using a Talbot-Lau interferometer and a stationary-anode x-ray tube. In this paper, theoretical principles and an experimental implementation of the corresponding CT imaging method are presented. First, a line integral is derived from analyzing the cross section of the small-angle scattering events. This method is referred to as small-angle scattering computed tomography (SAS-CT). Next, a Talbot-Lau interferometer and a rotating-anode x-ray tube were used to implement SAS-CT. A physical phantom and human breast tissue sample were used to demonstrate the reconstructed SAS-CT image volumes.Keywords
This publication has 35 references indexed in Scilit:
- X-ray dark-field and phase-contrast imaging using a grating interferometerJournal of Applied Physics, 2009
- Soft-tissue phase-contrast tomography with an x-ray tube sourcePhysics in Medicine & Biology, 2009
- Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-raysJournal of Synchrotron Radiation, 2008
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- High-resolution differential phase contrast imaging using a magnifying projection geometry with a microfocus x-ray sourceApplied Physics Letters, 2007
- Hard X-Ray Phase Tomography with Low-Brilliance SourcesPhysical Review Letters, 2007
- Phase Tomography by X-ray Talbot Interferometry for Biological ImagingJapanese Journal of Applied Physics, 2006
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006
- X-ray phase imaging with a grating interferometerOptics Express, 2005
- Demonstration of X-Ray Talbot InterferometryJapanese Journal of Applied Physics, 2003