Percutaneous Iliosacral Screw Insertion: Malpositioning and Revision Rate of Screws With Regards to Application Technique (Navigated Vs. Conventional)
Authors:
- J. ZwingmannJZJ. Zwingmann
- G. KonradGKG. Konrad
- A. T. MehlhornAMA. T. Mehlhorn
- N. P. SüdkampNSN. P. Südkamp
- M. OberstMOM. Oberst
- 1 December 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 69 (6) , 1501-1506
Abstract
Conventional percutaneous iliosacral screw placement in pelvic surgery is considered to be a highly demanding operative technique with a high rate of screw malpositions, which may be associated with the risk of neurologic damage or inefficient stability. In the conventional technique, the correct entry point for the screw and the small target corridor for the iliosacral screw may be difficult to visualize using an image intensifier. We tried to find out in this study whether the positioning of percutaneous screw implantations could be optimized by evaluating the rate and grade of malpositions and whether the needed revisions could be reduced by using computer navigation and three-dimensional (3D) image intensifier. A group of 54 patients with 63 screws implanted using computer navigation was compared with 87 patients with 131 screws implanted using the conventional fluoroscopic technique. The exact screw position was controlled in a postoperative computed tomography scan, and the grade of malposition of every screw was investigated and compared. A complete intraosseous screw position was found in 42% of cases using the conventional technique and was significantly less compared with 81% using a 3D image intensifier in combination with a navigation system. Moreover, the revision rate of 1.6% was significantly less in the navigated group compared with 19% in the conventional group. The results indicate that 3D-computer navigation of the percutaneous iliosacral screw insertion can facilitate surgical performance in respect to reducing screw malposition and revision rates.Keywords
This publication has 25 references indexed in Scilit:
- Computer-navigated Iliosacral Screw Insertion Reduces Malposition Rate and Radiation ExposureClinical Orthopaedics and Related Research, 2009
- Standard Multiplanar Fluoroscopy Versus a Fluoroscopically Based Navigation System for the Percutaneous Insertion of Iliosacral ScrewsJournal of Orthopaedic Trauma, 2005
- Accuracy of Computer-Guided Screw Fixation of the Sacroiliac JointClinical Orthopaedics and Related Research, 2001
- Percutaneous Iliosacral Screw Placement Using Image Guided TechniquesClinical Orthopaedics and Related Research, 1998
- Iliosacral Screw Insertion Using Computer-Assisted CT Image Guidance: a Laboratory StudyComputer Aided Surgery, 1998
- Pseudoaneurysm of the Superior Gluteal Arterial SystemThe Journal of Trauma: Injury, Infection, and Critical Care, 1997
- Closed Reduction and Percutaneous Skeletal Fixation of Sacral FracturesClinical Orthopaedics and Related Research, 1996
- Proximity of Iliosacral Screws to Neurovascular Structures After Internal FixationClinical Orthopaedics and Related Research, 1996
- Outcome After Fixation of Unstable Posterior Pelvic Ring InjuriesClinical Orthopaedics and Related Research, 1996
- Early Results of Percutaneous Iliosacral Screws Placed with the Patient in the Supine PositionJournal of Orthopaedic Trauma, 1995